4.0 Control Unit<br />

The information in this section provides<br />

the user with guidelines necessary for<br />

installation.<br />

Control Unit mounting location must first<br />

be considered. The Control Unit can be<br />

mounted indoors as well as outdoors. In<br />

order to avoid losses in speaker power, it<br />

is recommended that the speaker array<br />

and Control Unit be installed without<br />

lengthening the 40-foot interconnecting<br />

cable supplied. If it is necessary to make<br />

a longer cable run, increasing the wire<br />

size of the entire cable to 12 AWG or<br />

larger is recommended.<br />

Whether the Control Unit is installed<br />

indoors or outdoors, it should be located<br />

out of the reach of vandals. Additionally,<br />

control and battery enclosures are both<br />

supplied with hasps for padlocking<br />

securely.<br />

The Control system requires a 120<br />

VAC or 240 VAC 50-60 Hz power<br />

source (model dependent).<br />

Several methods can be used to activate<br />

the Control Unit. The <strong>Manual</strong> activation<br />

switches can be used to activate the<br />

Control Unit locally. Landline control can<br />

be used through normally open contact<br />

switches. Connections should be made<br />

directly to the motherboard terminal<br />

block. The control can also be remotely<br />

activated via the optional radio receiver or<br />

an external 600 ohm audio source.<br />

Federal Signal <strong>UltraVoice</strong><br />

Installation and Operation <strong>Manual</strong><br />

SECTION IV<br />

SYSTEM PLANNING<br />

SYSTEM PLANNING<br />

29<br />

The total weights of the Control and<br />

Battery Box assemblies, including user<br />

provided batteries, are listed. Insure that<br />

the mounting surface and fasteners can<br />

safely sustain the weight of the assembly.<br />

Note that each UV400 amplifier must be<br />

added to obtain the total weight.<br />

Model No. Weight<br />

UV 170 lbs.<br />

UV400 4.12 lbs. each<br />

4.1 Siren and Control Location<br />

WARNING<br />

The sound output of the Modulator<br />

series speaker arrays is capable of<br />

causing permanent hearing damage.<br />

Do not install speaker arrays where<br />

persons may come within 150 feet of<br />

the direct path of the array.<br />

If speaker array is roof mounted, post<br />

warnings at all roof access points.<br />

Many factors affect the propagation of<br />

sound over various types of terrain and<br />

changing weather conditions. Consult<br />

FEMA CPG 1-17 and CPG 1-14 and your<br />

local Federal Signal representative to<br />

properly place your outdoor warning<br />

equipment.