functions programmed for that code, can<br />
be activated by providing an additional<br />
momentary, dry contact closure<br />
between “COM” and the desired JP14<br />
terminal. Shorting “F1” to “COM” will<br />
activate whatever is programmed for<br />
code #1, shorting “F2” to “COM” will<br />
activate whatever is programmed for<br />
code #2 and so on. A half second<br />
momentary contact duration is required.<br />
To terminate an activated signal before<br />
it runs for the full duration, if desired:<br />
Provide a momentary contact closure<br />
between JP14 “COM” and “F8”<br />
(RESET).<br />
Remote Activation Connections:<br />
JP14 Terminal Function<br />
1 “Common”<br />
2 “F1”<br />
3 “F2”<br />
4 “F3”<br />
5 “F4”<br />
6 “F5”<br />
7 “F6”<br />
8 “F7”<br />
9 “F8”<br />
10 “Common”<br />
3.7 Sensor Inputs<br />
Terminal block JP15 at the bottom of the<br />
system motherboard is the Sensor<br />
Inputs. These are activated by a short to<br />
“Common”.<br />
Sensor Connections:<br />
JP15 Terminal Function<br />
1 “Common”<br />
2 “Spare #1”<br />
3 “Common”<br />
4 “Intrusion”<br />
5 “Common”<br />
Federal Signal <strong>UltraVoice</strong><br />
Installation and Operation <strong>Manual</strong><br />
6 “Solar”<br />
7 “Common”<br />
8 “AC Power”<br />
9 “Common”<br />
10 “600 PTT”<br />
11 “Common”<br />
12 “Spare #2”<br />
ELECTRONIC SIREN CONTROL OPERATION<br />
27<br />
Intrusion: Alerts the controller when one<br />
of the unit‟s doors has been<br />
opened. Low is intrusion pass<br />
Solar: Used to sense operation of<br />
solar power system.<br />
Jumper JP15: pins 5 to 6 and<br />
to enable solar sensing. Solar<br />
mode latches power sense to<br />
prevent low light conditions<br />
from causing failures. For<br />
solar panel test, initiate a<br />
reset, and then a poll.<br />
Immediate good power input<br />
required after a reset to pass.<br />
Jumper JP15 pins 7 to 8 AC<br />
sense is required if solar only<br />
unit.<br />
Spare<br />
1 & 2: Unused inputs for special<br />
functions.<br />
AC<br />
Power: Alerts the controller when the<br />
AC Power has failed. Open is<br />
fail. Closed is pass.<br />
600 Ohm<br />
PTT: Puts the unit in Local P.A.<br />
mode for input of external<br />
audio. Closed is active.