2.0 Electrical<br />

Federal Signal <strong>UltraVoice</strong><br />

Installation and Operation <strong>Manual</strong><br />

SECTION II<br />

SPECIFICATIONS<br />

Input Voltage 120 or 240 VAC 50 - 60 Hz*<br />

(*two separate models)<br />

Input Current 7 Amps maximum<br />

Battery Input Voltage 20-28 VDC 24 Volts (nominal)<br />

Battery Current 120 mA standby current,<br />

+18 - 22 Amps for each amplifier module<br />

running<br />

Maximum Signaling Time 30 minutes<br />

Stand By Time (with minimum<br />

5-minute full signal reserve) Greater than 168 hours (7 days)<br />

without 2-way radio<br />

2.1 Charger<br />

Current Limit Protected with automatic recovery<br />

EMI/RFI Filtering Meets FCC requirements<br />

Input 115 VAC (50 - 60 Hz), 3.5 A maximum<br />

Output Voltage 26 – 30 VDC (temperature compensated)<br />

Output Current 0 -10 Amps DC<br />

SPECIFICATIONS<br />