2.0 Electrical<br />
Federal Signal <strong>UltraVoice</strong><br />
Installation and Operation <strong>Manual</strong><br />
SECTION II<br />
SPECIFICATIONS<br />
Input Voltage 120 or 240 VAC 50 - 60 Hz*<br />
(*two separate models)<br />
Input Current 7 Amps maximum<br />
Battery Input Voltage 20-28 VDC 24 Volts (nominal)<br />
Battery Current 120 mA standby current,<br />
+18 - 22 Amps for each amplifier module<br />
running<br />
Maximum Signaling Time 30 minutes<br />
Stand By Time (with minimum<br />
5-minute full signal reserve) Greater than 168 hours (7 days)<br />
without 2-way radio<br />
2.1 Charger<br />
Current Limit Protected with automatic recovery<br />
EMI/RFI Filtering Meets FCC requirements<br />
Input 115 VAC (50 - 60 Hz), 3.5 A maximum<br />
Output Voltage 26 – 30 VDC (temperature compensated)<br />
Output Current 0 -10 Amps DC<br />
SPECIFICATIONS<br />