UltraVoice Manual - Alerting & Notification
UltraVoice Manual - Alerting & Notification
UltraVoice Manual - Alerting & Notification
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Site Address Switch:<br />
Unit Address<br />
The unit address sets the siren site<br />
number and is used to identify the site in<br />
two-way report back systems. The Unit<br />
Address is a three-digit number with a<br />
range of 001-1023. The unit address is<br />
set via dip switch S1. S1 Off position<br />
indicates active position. Add binary<br />
active switch positions to get ID<br />
address.<br />
Switch<br />
No. 1 2 3 4 5 6 7 8<br />
Binary<br />
No. 1 2 4 8 16 32 64 128<br />
Federal Signal <strong>UltraVoice</strong><br />
Installation and Operation <strong>Manual</strong><br />
9<br />
256<br />
10<br />
512<br />
Example: Switch number 1, 2 & 3 is<br />
binary number 1, 2 & 4, which when<br />
added, would equal unit address 7.<br />
Note: Must be set to address one to<br />
program controller board with hex code<br />
or to program a non-digital unit. When<br />
the programming is completed, change<br />
the dip switch setting to the actual site<br />
address. Programming details are in the<br />
software manual. The ID address is<br />
stored at power up of the controller. If<br />
the ID address is changed, the power<br />
GENERAL DESCRIPTION<br />
11<br />
(battery and AC) must be turned off and<br />
then on.<br />
RF Frequency<br />
For units equipped with the optional<br />
integral radio receiver, the RF<br />
Frequency configuration parameter sets<br />
the frequency of the radio channel.<br />
Changing this parameter from its factory<br />
setting will require re-alignment of the<br />
radio for maximum performance. The<br />
value entered must fall within the range<br />
specified for the receiver band<br />
equipped.<br />
Single-Tone, Two-Tone Timing<br />
For Two-Tone activated units, the<br />
Two-Tone Timing parameters set<br />
up the time duration of the<br />
activation tone codes. The three<br />
parameters, A-Time, B-Time and<br />
S-Time; sets the time duration for<br />
the A-tone, B-tone and Single-Tone<br />
respectively. Note: the Two-Tone<br />
timing parameters are minimum<br />
values only. The actual tone times<br />
may be longer than the specified<br />
times.<br />
1.3 User Programs<br />
The modular <strong>UltraVoice</strong> siren has the<br />
capacity to store up to fifty (50) user<br />
programs. Each user program contains<br />
the following elements:<br />
1. DTMF Activation Code OR<br />
2. Two-Tone Activation Code OR<br />
3. EAS Location & Event Codes OR<br />
4. POCSAG Activation Code OR<br />
5. Digital Activation Code # AND<br />
6. List of up to 20 functions