Site Address Switch:<br />

Unit Address<br />

The unit address sets the siren site<br />

number and is used to identify the site in<br />

two-way report back systems. The Unit<br />

Address is a three-digit number with a<br />

range of 001-1023. The unit address is<br />

set via dip switch S1. S1 Off position<br />

indicates active position. Add binary<br />

active switch positions to get ID<br />

address.<br />

Switch<br />

No. 1 2 3 4 5 6 7 8<br />

Binary<br />

No. 1 2 4 8 16 32 64 128<br />

Federal Signal <strong>UltraVoice</strong><br />

Installation and Operation <strong>Manual</strong><br />

9<br />

256<br />

10<br />

512<br />

Example: Switch number 1, 2 & 3 is<br />

binary number 1, 2 & 4, which when<br />

added, would equal unit address 7.<br />

Note: Must be set to address one to<br />

program controller board with hex code<br />

or to program a non-digital unit. When<br />

the programming is completed, change<br />

the dip switch setting to the actual site<br />

address. Programming details are in the<br />

software manual. The ID address is<br />

stored at power up of the controller. If<br />

the ID address is changed, the power<br />

GENERAL DESCRIPTION<br />

11<br />

(battery and AC) must be turned off and<br />

then on.<br />

RF Frequency<br />

For units equipped with the optional<br />

integral radio receiver, the RF<br />

Frequency configuration parameter sets<br />

the frequency of the radio channel.<br />

Changing this parameter from its factory<br />

setting will require re-alignment of the<br />

radio for maximum performance. The<br />

value entered must fall within the range<br />

specified for the receiver band<br />

equipped.<br />

Single-Tone, Two-Tone Timing<br />

For Two-Tone activated units, the<br />

Two-Tone Timing parameters set<br />

up the time duration of the<br />

activation tone codes. The three<br />

parameters, A-Time, B-Time and<br />

S-Time; sets the time duration for<br />

the A-tone, B-tone and Single-Tone<br />

respectively. Note: the Two-Tone<br />

timing parameters are minimum<br />

values only. The actual tone times<br />

may be longer than the specified<br />

times.<br />

1.3 User Programs<br />

The modular <strong>UltraVoice</strong> siren has the<br />

capacity to store up to fifty (50) user<br />

programs. Each user program contains<br />

the following elements:<br />

1. DTMF Activation Code OR<br />

2. Two-Tone Activation Code OR<br />

3. EAS Location & Event Codes OR<br />

4. POCSAG Activation Code OR<br />

5. Digital Activation Code # AND<br />

6. List of up to 20 functions