Contact your sales representative for<br />
stainless steel options.<br />
For DSA series sirens, the total<br />
number of speakers to be used<br />
with each <strong>UltraVoice</strong>+ controller<br />
must be determined. Each DSA<br />
model number is based on the<br />
quantity of speakers it contains.<br />
Since each speaker is a 100 W<br />
speaker, the quantity of amplifiers<br />
can be determined using the<br />
tables below.<br />
For example: If (4) DSA2 arrays are<br />
used with (1) <strong>UltraVoice</strong>+ controller, 4 x<br />
200 Watts = 800 Watts or (2) UV400<br />
amplifiers<br />
UV400 AMPLIFIER SELECTION CHART<br />
FOR MOD SERIES SIRENS<br />
(see paragraph below for DSA speakers)<br />
QTY SIREN TOTAL<br />
TYPE POWER<br />
(1) UV400 MOD1004 400 Watts<br />
(2) UV400 MOD2008 800 Watts<br />
(3) UV400 MOD3012 1200 Watts<br />
(4) UV400 MOD4016 1600 Watts<br />
(5) UV400 MOD5020 2000 Watts<br />
(6) UV400 MOD6024 2400 Watts<br />
(8) UV400 MOD6032 3200 Watts<br />
(12) UV400 MOD6048 4800 Watts<br />
DSA POWER RATING CHART<br />
MODEL TOTAL POWER<br />
DSA1 100 Watts<br />
DSA2 200 Watts<br />
DSA3 300 Watts<br />
DSA4 400 Watts<br />
DSA5 500 Watts<br />
DSA6 600 Watts<br />
Notes: 1. Each UV400 amplifier is a<br />
400-Watt amplifier. Therefore,<br />
Federal Signal <strong>UltraVoice</strong><br />
Installation and Operation <strong>Manual</strong><br />
GENERAL DESCRIPTION<br />
10<br />
consult the chart above to<br />
determine how many amplifiers<br />
are required to drive DSA siren<br />
combinations. DSA speakers<br />
must be used in 400W<br />
increments with UV400<br />
amplifiers.<br />
1.2 Configuration<br />
Each modular <strong>UltraVoice</strong> siren contains<br />
the following configuration parameters<br />
that are configured by the user:<br />
1. Unit Type<br />
2. Unit Address (see below)<br />
3. RF Frequency<br />
4. Single-Tone or Two-Tone Timing<br />
(A-time, B-time, S-time)<br />
Unit Type:<br />
The Unit Type is set to the type of siren<br />
this unit is controlling, and is usually<br />
determined by the number of cells in the<br />
speaker array. When setting up the unit<br />
type, the user selects from a menu with<br />
the following choices:<br />
EOWS-612 Directional Siren<br />
UV with 1 Amp 1-Cell - 400W siren<br />
UV 2 Amps 2-Cell - 800W siren<br />
UV 3 Amps 3 Cell - 1200W siren<br />
UV 4 Amps 4 Cell - 1600W siren<br />
UV 5 Amps 5 Cell - 2000W siren<br />
UV 6 Amps 6 Cell - 2400W siren<br />
*UV 8 Amps 6 Cell - 3200W siren<br />
*UV 12 Amps 6 Cell - 4800W siren<br />
*(2 controls and 2 battery cabinets req.)