Contact your sales representative for<br />

stainless steel options.<br />

For DSA series sirens, the total<br />

number of speakers to be used<br />

with each <strong>UltraVoice</strong>+ controller<br />

must be determined. Each DSA<br />

model number is based on the<br />

quantity of speakers it contains.<br />

Since each speaker is a 100 W<br />

speaker, the quantity of amplifiers<br />

can be determined using the<br />

tables below.<br />

For example: If (4) DSA2 arrays are<br />

used with (1) <strong>UltraVoice</strong>+ controller, 4 x<br />

200 Watts = 800 Watts or (2) UV400<br />

amplifiers<br />

UV400 AMPLIFIER SELECTION CHART<br />

FOR MOD SERIES SIRENS<br />

(see paragraph below for DSA speakers)<br />

QTY SIREN TOTAL<br />

TYPE POWER<br />

(1) UV400 MOD1004 400 Watts<br />

(2) UV400 MOD2008 800 Watts<br />

(3) UV400 MOD3012 1200 Watts<br />

(4) UV400 MOD4016 1600 Watts<br />

(5) UV400 MOD5020 2000 Watts<br />

(6) UV400 MOD6024 2400 Watts<br />

(8) UV400 MOD6032 3200 Watts<br />

(12) UV400 MOD6048 4800 Watts<br />

DSA POWER RATING CHART<br />

MODEL TOTAL POWER<br />

DSA1 100 Watts<br />

DSA2 200 Watts<br />

DSA3 300 Watts<br />

DSA4 400 Watts<br />

DSA5 500 Watts<br />

DSA6 600 Watts<br />

Notes: 1. Each UV400 amplifier is a<br />

400-Watt amplifier. Therefore,<br />

Federal Signal <strong>UltraVoice</strong><br />

Installation and Operation <strong>Manual</strong><br />

GENERAL DESCRIPTION<br />

10<br />

consult the chart above to<br />

determine how many amplifiers<br />

are required to drive DSA siren<br />

combinations. DSA speakers<br />

must be used in 400W<br />

increments with UV400<br />

amplifiers.<br />

1.2 Configuration<br />

Each modular <strong>UltraVoice</strong> siren contains<br />

the following configuration parameters<br />

that are configured by the user:<br />

1. Unit Type<br />

2. Unit Address (see below)<br />

3. RF Frequency<br />

4. Single-Tone or Two-Tone Timing<br />

(A-time, B-time, S-time)<br />

Unit Type:<br />

The Unit Type is set to the type of siren<br />

this unit is controlling, and is usually<br />

determined by the number of cells in the<br />

speaker array. When setting up the unit<br />

type, the user selects from a menu with<br />

the following choices:<br />

EOWS-612 Directional Siren<br />

UV with 1 Amp 1-Cell - 400W siren<br />

UV 2 Amps 2-Cell - 800W siren<br />

UV 3 Amps 3 Cell - 1200W siren<br />

UV 4 Amps 4 Cell - 1600W siren<br />

UV 5 Amps 5 Cell - 2000W siren<br />

UV 6 Amps 6 Cell - 2400W siren<br />

*UV 8 Amps 6 Cell - 3200W siren<br />

*UV 12 Amps 6 Cell - 4800W siren<br />

*(2 controls and 2 battery cabinets req.)