368 APPENDIX 4<br />

PROFORMA 3-D OF APPENDIX - 4<br />

CENTRAL PUBLIC WORKS DEPARTMENT<br />

No. Dated, the<br />

To<br />

The Executive Engineer,<br />

.............................<br />

.............................<br />

Name of Work:<br />

Kindly furnish the following information for the above work of Storm Water Drainage of the area as<br />

early as possible in order to enable this office to prepare project estimate for the same.<br />

1. Give a survey plan of the area for which the Drainage system is to be designed showing the spot<br />

levels at intervals of 60m and proposed layout of roads and buildings. Formation levels of ground<br />

along side of the roads and crown levels of roads may be given at intervals of 60m.<br />

2 (a) If the area forms of part of a bigger catchment, a site and contour plan of the entire catchment<br />

area should be given.<br />

(b) If it is likely that drainage from the upper portion of the catchment enters the area now proposed<br />

to be developed, suggest measures to intercept the drainage or indicate the probable additional<br />

run off to be allowed for.<br />

3. The maximum intensity of the rainfall in the area and its duration and the total annual rainfall.<br />

4. Nature of the soil and vegetation in the area.<br />

5. Full particulars of any natural water course or Nallah passing near the area into which the area<br />

under consideration can be drained, together with the HFL in the storm water drainage. A plan<br />

showing the Nallah and “L” section of the Nallah showing the HFL for about 400 metres above and<br />

below the point where it is proposed to discharge the drainage into the Nallah may also be supplied.<br />

For Superintending Engineer(P)<br />

.............. Zone, CPWD.<br />

No. Dated, the<br />

Copy forwarded to:<br />

1. The Executive Engineer (Electrical) .............. Division .............. for furnishing the information in<br />

connection with the existing electric mains, their distance from the area, type of power available and<br />

adequacy of electric energy etc.<br />

2. The Superintending Engineer .............. Circle, CPWD, for information.<br />

3. The Superintending Engineer .............. Electrical Circle, CPWD, for information.<br />

For Superintending Engineer(P)<br />

.............. Zone, CPWD.