- 18 -<br />

5. New Developments in Instrumentation<br />

5 • ^ • On-line Computers G. Krüger<br />

5•1•1• Small On-line Computers Coupled with Experiments<br />

The electronic design and development of the multiple access system<br />

MIDAS were finished during the reporting period. After Connection of<br />

some new nuclear physics experiments 8 facilities are in normal<br />

operation with the system.<br />

The total input capacity of MIDAS (Multiple Input <strong>Data</strong> Acquisition<br />

System) amounts to 10 experiments, two of them can be located at<br />

remote places. They are connected by fast data transmission lines.<br />

During the year most activity concerns the development work in the<br />

fields of programming and system organisation £1 J'. Privât libraries<br />

for the measuring programs of the experimentors were established on<br />

the IBM 1J11 disc, units. The archived programs in the different libraries<br />

can be activated by experimentor's command using the command panel<br />

at the location of the experiment.<br />

The operation of MIDAS as an on-line-real-time multichannel<br />

analyser with a capacity of about 262.000 channels has proven very<br />

useful during routine operation. To accumulate multiparameter data<br />

directly without delay a new programmed method of list-processing<br />

were implemented.<br />

The program package which should ensure system integrity during periods<br />

of wrong running experiments was extended. The computer indentifies<br />

now immediately experiment malfunctions which overload the computer.<br />

Then the safety system closes the erroneous data way without inter­<br />

fering the correct running measurements.<br />

The check point program is now a standard feature of the system.<br />

This program in connection with the new time-of-the-day real-time<br />

clock interrupts the system in regular intervalls. The recent status<br />

and all the intermediat-3 results of the different measurements are<br />

saved into magnetic tape. Therefore a total breakdown of the system<br />

cannot destroy large amount of measuring results.<br />