- 159 -<br />

4-.4-.5. Random Digital Word Generator<br />

A unit generating binary coded digital words with up<br />

to 20-bit length, random in distance and address, and<br />

simulating therefore experimental conditions has been<br />

developed for the overall test of digital data handling<br />

equipment. The generated spectrum is equivalent to a<br />

white noise spectrum.<br />

5. Radionuclides<br />

5.1. Standardization<br />

An international BIPM intercomparison of dilution<br />

techniques using Go solutions, in which the CBNM<br />

took part, showed that only an error of about 0.05%<br />

could be attributed to our source preparation, while<br />

no significant error (j> 0.02%) was found on the dilution<br />

of the solutions.<br />

An international intercomparison of threshold detectors<br />

and reactor spectra was organized. About 180 sources<br />

from about 10 different reactors were compared.<br />

The total decay rates were determined by integral<br />

counting with our 3" x 5" NaJ detector, the impurities<br />

by our 1.1 cm^ Ge(Li)-detector. All measurements are<br />

completed, but theucalculation will still require some<br />

time.<br />

24-1<br />

An intercomparison of Am was made using all possible<br />

methods: low geometry, liquid scintillation, 4TT and<br />

4-TTa-Y-coincidence. It showed that Am can be standardized<br />

with.0.1% accuracy, but also that this is a<br />

limit at present, caused by all kinds of noise and<br />

physical second order effects. The latter conclusion<br />

seems to be a rather general result from our recent<br />

241<br />

work. This Am solution, the activity of which is<br />

known to better than 0.1%, is also available to other<br />

laboratories, as are several other radioisotopes calibrated<br />

with extreme accuracy before.