4-.4-.5. Random Digital Word Generator<br />
A unit generating binary coded digital words with up<br />
to 20-bit length, random in distance and address, and<br />
simulating therefore experimental conditions has been<br />
developed for the overall test of digital data handling<br />
equipment. The generated spectrum is equivalent to a<br />
white noise spectrum.<br />
5. Radionuclides<br />
5.1. Standardization<br />
An international BIPM intercomparison of dilution<br />
techniques using Go solutions, in which the CBNM<br />
took part, showed that only an error of about 0.05%<br />
could be attributed to our source preparation, while<br />
no significant error (j> 0.02%) was found on the dilution<br />
of the solutions.<br />
An international intercomparison of threshold detectors<br />
and reactor spectra was organized. About 180 sources<br />
from about 10 different reactors were compared.<br />
The total decay rates were determined by integral<br />
counting with our 3" x 5" NaJ detector, the impurities<br />
by our 1.1 cm^ Ge(Li)-detector. All measurements are<br />
completed, but theucalculation will still require some<br />
time.<br />
24-1<br />
An intercomparison of Am was made using all possible<br />
methods: low geometry, liquid scintillation, 4TT and<br />
4-TTa-Y-coincidence. It showed that Am can be standardized<br />
with.0.1% accuracy, but also that this is a<br />
limit at present, caused by all kinds of noise and<br />
physical second order effects. The latter conclusion<br />
seems to be a rather general result from our recent<br />
241<br />
work. This Am solution, the activity of which is<br />
known to better than 0.1%, is also available to other<br />
laboratories, as are several other radioisotopes calibrated<br />
with extreme accuracy before.