Operating Instructions<br />
18<br />
SLOW CHARGE PROCEDURE<br />
WARNING<br />
Before starting the vehicle's engine, verify that it is in PARK or<br />
NEUTRAL, with the emergency brake ON.<br />
Never run a vehicle without adequate ventilation in the work area.<br />
CAUTION! Close the high side manifold valve before starting the<br />
vehicle A/C system.<br />
1. Close the High Side Valve. Put the Low Side Valve in the Recover/Vacuum<br />
position.<br />
2. Start the vehicle, and set the AC system to its maximum setting.<br />
3. Press START. The unit charges out of the low side inlet only, allowing the<br />
vehicle's compressor to pull the refrigerant into the A/C system.<br />
4. When the unit is finished charging, the display reads:<br />
CHARGE COMPLETE<br />
X.XX lb (kg) CHARGED<br />
5. Close the LOW SIDE manifold valve.<br />
6. Turn off the vehicle's engine.<br />
7. For R-<strong>134a</strong> systems, close the high and low side coupler valves. Remove the<br />
service hoses from the A/C system.<br />
The A/C system is now ready for use.<br />