Operating Guidelines<br />

USING THE CONTROL PANEL<br />

The control panel has various components that control specific operating functions.<br />

MAIN POWER SWITCH—Supplies electrical power to the control panel.<br />

DIGITAL DISPLAY—Used on the visual interface between the operator and<br />

the machine.<br />

LOW SIDE MANIFOLD GAUGE—Connects to an A/C system and shows the<br />

system’s low side pressure.<br />

HIGH SIDE MANIFOLD GAUGE—Connects to an A/C system and shows the<br />

system’s high side pressure.<br />

LOW SIDE VALVE—Controls the low side flow from the A/C system through<br />

the unit.<br />

HIGH SIDE VALVE—Controls the high side flow from the A/C system through<br />

the unit. It has three positions: 1) Recover/Vacuum, 2) Closed, 3) Oil Inject/Charge.<br />

6<br />

7<br />

10<br />

3 0<br />

2 0<br />

1<br />

0<br />

1<br />

0<br />

0<br />

0<br />

4<br />

2 0<br />

0<br />

0<br />

3<br />

RECOVER<br />

VACUUM<br />

0<br />

1<br />

5<br />

0<br />

0 0<br />

2<br />

3<br />

0<br />

R-134A<br />

bar<br />

kPa<br />

in Hg<br />

VAC<br />

psi<br />

3<br />

4<br />

0<br />

0<br />

6 0<br />

0 0<br />

4<br />

2<br />

5<br />

8<br />

R E<br />

4<br />

5<br />

0<br />

0<br />

7 0<br />

0 0 6<br />

6<br />

8<br />

7<br />

0<br />

0<br />

8<br />

8 0<br />

T AR D 0<br />

12<br />

0 9<br />

0<br />

0<br />

7<br />

0<br />

0<br />

1<br />

0 1<br />

1<br />

0<br />

0<br />

CLOSED CLOSED<br />

RECOVER<br />

VACUUM<br />

10 0<br />

5 0<br />

1<br />

1 0<br />

0<br />

0<br />

5<br />

5<br />

0<br />

0<br />

0<br />

0<br />

2 0<br />

1<br />

0<br />

1<br />

5<br />

5<br />

0<br />

R-134A<br />

0<br />

0<br />

1<br />

0<br />

5<br />

2<br />

5<br />

0<br />

bar<br />

kPa<br />

psi<br />

2<br />

2<br />

0<br />

4<br />

3<br />

HIGH<br />

0<br />

00<br />

5 0<br />

0<br />

0<br />

2 5<br />

0<br />

0<br />

3<br />

3<br />

0<br />

0<br />

3 0<br />

2 0<br />

5<br />

0<br />

0<br />

0<br />

4 5<br />

0<br />

OIL INJECT<br />

CHARGE<br />

3<br />

5<br />

0<br />

1 2<br />

4 0<br />

0<br />

RECOVER VACUUM VAC-CHARGE<br />

MENU<br />

START<br />

CLEAR<br />

8<br />

0<br />

STOP<br />

1 2 3<br />

4 5 6<br />

7 9<br />

Diagram of Control Panel<br />

1. Low Side Gauge<br />

5. Main Power Switch<br />

2. High Side Gauge 6. Low Side Valve<br />

3. Display<br />

7. High Side Valve<br />

4. Bezel & Keypad Assembly<br />

ENTER<br />

CHARGE<br />

F1<br />

0<br />

I<br />

5<br />

3<br />

4<br />

INST0926<br />

© 2001 <strong>Robinair</strong>, SPX Corporation