In-the-Ceiling Type<br />

PDAP-FSN2<br />

Remote Control Switch<br />

PLPAR<br />

Wireless Remote Controller<br />

PC-LH3A<br />

Remote control switch and wireless<br />

remote controller are both options.<br />

Quiet Operation and Low Height Design for Limited Space Inside of the Ceiling<br />

Broader Range of External Static Pressure.<br />

Flexibly Supports a Wide Range of Installation<br />

Conditions at Site, e.g. Longer Ducts.<br />

In addition to the standard Hi-Me-Lo, the speed-up tap<br />

can be set by remote control. Available for external static<br />

pressure of up to 80 Pa for P22 to P71 and 170 Pa for<br />

P90 to P140.<br />

Space-saving Design<br />

Less than 270 mm in height, this unit can fit into practically<br />

any previously existing false ceiling or formerly ducted<br />

space without substantial modification (P22 to P71).<br />

(P22 to P71)<br />

270mm<br />

Minimum 5mm<br />

False Ceiling<br />

Dimensions correspondence chart<br />

Size<br />

Model<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

H<br />

I<br />

J<br />

K<br />

L<br />

Size<br />

Model<br />

M<br />

N<br />

P<br />

Q<br />

R<br />

S<br />

T<br />

U<br />

V<br />

W<br />

X<br />

Y<br />

P22<br />

650<br />

730<br />

1<br />

300<br />

215<br />

553<br />

583<br />

6.35<br />

12.7<br />

70<br />

92<br />

10<br />

P28 P45 P56<br />

650<br />

730<br />

1<br />

300<br />

215<br />

553<br />

583<br />

6.35<br />

12.7<br />

70<br />

92<br />

10<br />

650<br />

730<br />

1<br />

300<br />

215<br />

553<br />

583<br />

6.35<br />

12.7<br />

70<br />

92<br />

10<br />

900<br />

980<br />

2<br />

600<br />

190<br />

803<br />

833<br />

6.35<br />

15.88<br />

77<br />

92<br />

12<br />

P71 P90<br />

900<br />

980<br />

2<br />

600<br />

190<br />

803<br />

833<br />

9.53<br />

15.88<br />

77<br />

95<br />

12<br />

900<br />

980<br />

2<br />

600<br />

190<br />

803<br />

833<br />

9.53<br />

15.88<br />

78<br />

95<br />

12<br />

P112 P140<br />

900<br />

980<br />

2<br />

600<br />

190<br />

803<br />

833<br />

9.53<br />

15.88<br />

81<br />

95<br />

12<br />

1,300<br />

1,380<br />

3<br />

900<br />

240<br />

1,203<br />

1,233<br />

9.53<br />

15.88<br />

81<br />

95<br />

14<br />

P22 P28 P45 P56 P71 P90 P112 P140<br />

676 676 676 676 676 756 756 756<br />

720 720 720 720 720 800 800 800<br />

23 23 23 23 23 103 103 103<br />

270 270 270 270 270 350 350 350<br />

182 182 182 182 182 204 204 204<br />

222 222 222 222 222 244 244 244<br />

43 43 43 43 43 123 123 123<br />

220 220 220 220 220 300 300 300<br />

100 100 100 100 100 140 140 140<br />

200 200 200 200 200 280 280 280<br />

226 226 226 226 226 306 306 306<br />

For the Y dimensions, install the drain pipe at a height that ensures sufficient slope.