MORLEY-IAS ZX <strong>Fire</strong> Alarm Control <strong>Panels</strong><br />
3.4.3.3 Adding Loop Driver Cards.<br />
+25V<br />
• An additional power cable is incorporated in the ZXSe range of fire panels.<br />
• Connect the spare cable from the PSU wiring loom to either of the two connections shown on the<br />
Loop driver card, then use the supplied cable to ‘daisy chain’ subsequent Loop drivers if required.<br />
No further connection is required for the last Loop driver card and the supplied cable can be<br />
discarded.<br />
RELAY 1<br />
ZX2Se<br />
RELAY 1<br />
ZX1Se<br />
COM N/C N/O COM N/C N/O<br />
RELAY 2<br />
3.4.3.4 Panel Loop Loading<br />
RELAY 2<br />
ZX5Se<br />
Figure 13– Adding Loop Driver Cards – ZX1Se / ZX2Se / ZX5Se<br />
• Care must be taken to ensure that the number of signalling loop devices (inputs and outputs)<br />
installed does not exceed the power supply ratings of each individual loop driver board and of the<br />
panel (all loops) in both quiescent and alarm conditions.<br />
1. Loop Driver Board Load (Refer to the documentation supplied with the loop driver)<br />
2. Overall Panel Load (Refer to Specification Tables – Section 6).<br />
Page 16 Document No. 996-174-000-1, Revision: 01 <strong>Installation</strong> <strong>Manual</strong>