ENGLISH – SK6 Installation manual<br />
Description<br />
The security unit SK6 is used in high security areas.<br />
It prevents unauthorised persons from opening the<br />
door by short-circuit the conductors to the electric<br />
release. It also protects for any manipulating the<br />
relay.<br />
The SK6 is tested against tamper attempt and relay<br />
manipulation for K44Duo, BM3/BM31, TP5/M65 and<br />
BC615 which are equipped with a tamper switch for<br />
external connection. Optionally it is possible to<br />
extend the relay manipulation protection by installing<br />
a reed-switch*).<br />
Note that the K42 does not need a reed-switch as<br />
the protection is built-in to the unit.<br />
It is recommended to wait at least 15 seconds after<br />
all wiring and power up before testing the units.<br />
*) See items 11 and 16 in illustration.<br />
Tamper control<br />
The security unit SK6 includes a relay that breaks<br />
the connection between the lock relay and the<br />
electric release when the protected unit’s housing is<br />
opened. This forms a “split-mount” solution.<br />
Note! This applies only for products with a tamper<br />
switch.<br />
Alarm output. If the cover of the protected unit is<br />
opened, the SK6 can also output a signal to an<br />
external alarm control system. The buzzer also<br />
starts to sound.<br />
Relay manipulation<br />
If the door unit does not include the metal parts to<br />
protect the lock relay from manipulation, SK6 offers<br />
the reed-switch option.<br />
K44Duo, BM3/BM31, TP5/M65 and<br />
BC615<br />
These units can optionally be installed with a reedswitch<br />
to sense any magnetic field manipulation of<br />
the lock relay.<br />
K42<br />
Via the built-in protection SK6 can determine if the<br />
activation of the lock relay is valid or not.<br />
Output signal<br />
Relay manipulation output. If the lock relay in<br />
the protected unit is manipulated (trying to unlock<br />
the door) there is a separate output signal.<br />
2<br />
Reset to normal<br />
There are two ways to reset the SK6 to normal<br />
function:<br />
Manual reset. The tamper alarm output is<br />
activated until a manual press on the button on<br />
the SK6 (see label on unit). The buzzer is also<br />
turned off.<br />
External signal. A signal from an external<br />
system may be connected to perform a reset.<br />
Note that if the protected unit is still in the wrong<br />
status when the reset occurs, there will be a new<br />
alarm generated (and buzzer sounds again).<br />
Safety<br />
General safety precautions<br />
Read the general safety precautions before<br />
operating the device.<br />
Follow all warnings and instructions marked on<br />
the device.<br />
Keep this document for reference.<br />
Always pass this document on together with the<br />
product.<br />
The device has been approved for use in the<br />
European Union. In countries outside the EU, the<br />
local conditions and regulations need to be<br />
checked before putting the device into service.<br />
Please also take into account any additional<br />
country-specific, local safety standards or<br />
regulations concerning project planning,<br />
operation and disposal of the product.<br />
The device should only be mounted indoors.<br />
Target group<br />
Installer with expert knowledge of building<br />
installation technique or electronic installations.<br />
Standards and guidelines<br />
This product complies with the requirements of the<br />
European Directives. The European declaration of<br />
conformity is available from:<br />
<strong>Siemens</strong> <strong>AB</strong>, Security Products<br />
Englundavägen 7<br />
SE-171 24 Solna, Sweden<br />
European Directive 2004/108/EC on Electromagnetic<br />
Compatibility (EMC):<br />
Compliance with the European Directive<br />
2004/108//EC has been proven by testing according<br />
to the following standards:<br />
Immunity EN61000-6-3<br />
Emission EN 50130-4<br />
Technical data<br />
Supply voltage (nom.*): 12 – 24 V AC/DC.<br />
Absolute voltage<br />
ratings**:<br />
10 – 35 VDC or<br />
8 – 24 VAC.<br />
Current consumption: Stand by power<br />
12V DC: 20 mA<br />
24V DC: 25 mA<br />
Full on<br />
12V DC: 50 mA<br />
24V DC: 85 mA<br />
Temperature range: 0 to +50°C<br />
Dimensions (H x W x D): 120 x 80 x 40 mm.<br />
* Nominal voltage has margins for transformer<br />
tolerances, mains supply variations and<br />
interruptions.<br />
** Absolute voltage has no margins and should be<br />
used for guidance only.<br />
Details of ordering<br />
Type Item Number Description<br />
SK6 S54513-F55-A1 Security Unit<br />