Comm<strong>and</strong>/response table for SIS comm<strong>and</strong>s (continued)<br />

Comm<strong>and</strong> ASCII (Telnet) URL Encoded (Web) Response<br />

Streaming files via Telnet or RS-232<br />

Load file to user flash memory24 28 Esc + UF file size, filename raw unprocessed data in file up to file size Upl<br />

If there is insufficient space on a device to store the sent file, the response is Fld (failed), instead of Upl (uploaded).<br />

You can use this comm<strong>and</strong> to update firmware by loading a file with a .s19 extension. If the device determines that the .s19 file is not intended for this product, the Upl<br />

response is followed by a Fwm (firmware mismatch) response.<br />

Retrieve file from user flash memory24 28 Esc filename SF 1B filename 53 46 0D Four bytes of file size + raw unprocessed<br />

data in file<br />

Streaming files via port 80<br />

Load file to user flash memory24 28 Use a POST on port 80, followed by the delimited date to be written to the flash file memory.<br />

Retrieve file from user flash memory Send a page GET on port 80, followed by WSF|. Raw unprocessed data in file<br />

Example: http://192.168.254.254/mypage.html?cmd=WSF|<br />

Event control<br />

Read event buffer memory27 Esc X35 , X36 , X37 X38 E W X35 %2C X36 %2C X37 X38 E| X54<br />

Write event buffer memory24 27 Esc X35 , X36 , X37 , X39 X38 E W X35 %2C X36 %2C X37 %2C X39 X38 E| Evt X35 , X36 , X37 , X39<br />

The response to the Write Event comm<strong>and</strong> is padded with leading zeros for X35 <strong>and</strong> X37 . X35 is 5 digits; X37 is 10 digits.<br />

Read string from event buffer memory27 Esc X35 , X36 , X37 , X44 FE W X35 %2C X36 %2C X37 %2C X44 FE| string<br />

Write string to event buffer memory24 27 Esc string * X35 , X36 , X37 FE W X39 %2A X35 %2C X36 %2C X37 FE| Evt X35 , X36 , X37 , string<br />

F must be capitalized in order for strings to be read <strong>and</strong> written to event buffer memory.<br />

The response to the Write Event comm<strong>and</strong> is padded with leading zeros for X35 <strong>and</strong> X37 . X35 is 5 digits; X37 is 10 digits.<br />

The Write String comm<strong>and</strong> requires an escaped string. Strings returned by the device (read or write response) are binary (non-escaped) data.<br />

Start Events24 27 Esc 1AE W1AE| Ego<br />

Stop Events24 27 Esc 0AE W0AE| Est<br />

Query number of events running Esc AE WAE| ##### (5 digit number)<br />

With tagged response – verbose modes<br />

2 <strong>and</strong> 3:<br />

Enm ##### (5 digit number)<br />