Ethernet Configuration and Control, cont'd - Extron Electronics
Ethernet Configuration and Control, cont'd - Extron Electronics
Ethernet Configuration and Control, cont'd - Extron Electronics
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Comm<strong>and</strong>/response table for SIS comm<strong>and</strong>s (continued)<br />
Comm<strong>and</strong> ASCII (Telnet) URL Encoded (Web) Response<br />
Web browser-specific comm<strong>and</strong>s<br />
Read response from last URL cmd Esc UB WUB| Response from comm<strong>and</strong><br />
IP setup<br />
Set the unit name24 Esc X12 CN W X12 CN Ipn X12<br />
Set unit name to factory default24 Esc CN W%20CN| Ipn X49<br />
View unit name Esc CN WCN| X12<br />
Set date/time24 Esc X13 CT W X13 CT| Ipt X13<br />
Example: 11/18/03-10:54:00<br />
View date/time Esc CT WCT|<br />
Example: Tue, 18 Nov 2003 18:19:33<br />
Set GMT offset24 Esc X3 CZ W X3 CZ| Ipz X3<br />
View GMT offset Esc CZ WCZ| X3<br />
Set daylight savings time24 Esc X34 CX W X34 CX| Ipx X34<br />
View daylight savings time Esc CX WCX| X34<br />
Set DHCP on24 Esc 1 DH W 1DH| Idh 1<br />
Set DHCP off24 Esc 0 DH W 0DH| Idh 0<br />
Changing DHCP from On to Off resets the IP address to the factory default (192.168.254.254).<br />
View DHCP mode Esc DH WDH| X5<br />
Set IP address24 Esc X14 CI W X14 CI| Ipi X14<br />
View IP address Esc CI WCI| X14<br />
View hardware address (MAC) Esc CH WCH| X18<br />
With tagged response – verbose modes<br />
2 <strong>and</strong> 3:<br />
Iph X18<br />
Set subnet mask24 Esc X19 CS W X19 CS| Ips X19<br />
View subnet mask Esc CS WCS| X19<br />
Set gateway IP address24 Esc X14 CG W X14 CG| Ipg X14<br />
View gateway IP address Esc CG WCG| X14<br />
IPL T PC1 SIS Programming <strong>and</strong> <strong>Control</strong><br />
Set verbose mode24 Esc X22 CV W X22 CV| Vrb X22<br />
The IPL T PC1 can send out unsolicited information (such as notice of a power level change). This is called a verbose (wordy) relationship between the interface <strong>and</strong> a connected<br />
device. When connected via <strong>Ethernet</strong>, verbose mode is disabled (by default) in order to reduce the amount of communication traffic on the network. If you want to use the<br />
verbose mode with an IPL T PC1 connected via <strong>Ethernet</strong>, this mode must be set to ON each time you reconnect to the network.<br />
5-11<br />
PRELIMINARY