PRELIMINARY<br />

SIS Programming <strong>and</strong> <strong>Control</strong>, cont’d<br />

Comm<strong>and</strong>/response table for SIS comm<strong>and</strong>s<br />

5-8<br />

Comm<strong>and</strong> ASCII (Telnet) URL Encoded (Web) Response<br />

Bi-directional serial data port<br />

Send data string Esc 1* X17 * X20 * X21 RS X2 W1%2A X17 %2A X20 %2A X21 RS| X2 response from comm<strong>and</strong><br />

Configure parameters24 Esc 1* X25 , X26 , X27 , X28 CP W1%2A X25 %2C X26 %2C X27 %2C X28 CP| Cpn 1 Ccp X25 , X26 , X27 , X28<br />

View parameters Esc 1CP W1CP| X25 , X26 , X27 , X28<br />

Configure flow control24 Esc 1* X30 , X31 CF W1%2A X30 %2C X31 CF| Cpn 1 Cfl X30 , X31<br />

View flow control Esc 1CF W1CF| X30 , X31<br />

Configure receive timeout Esc 1* X17 * X20 * X23 * X21 CE W1%2A X17 %2A X20 %2A X23 %2A X21 CE| Cpn 1 Cce X17 , X20 , X23 , X21<br />

View receive timeout Esc 1CE W1CE| X17 , X20 , X23 , X21<br />

IR data port<br />

Send IR comm<strong>and</strong>28 Esc 1, X57 , X58 , X59 IR W1 %2C X57 %2C X58 %2C X59 IR| Irs 1, X57 , X58 , X59<br />

Get IR comm<strong>and</strong> information 28 Esc X57 , X58 IR W X57 %2C X58 IR| Descriptive text<br />

IPL T PC1 SIS Programming <strong>and</strong> <strong>Control</strong><br />

Contact closure port<br />

View input state 1 ] 1%5D X42<br />

With tagged response – verbose modes<br />

2 & 3:<br />

Cpn01 Sio X42<br />

Power receptacle control<br />

Turn receptacle power on Esc 1* 1PC W1%2A1PC| Cpn01 Ppc 1<br />

Turn receptacle power off Esc 1* 0PC W1%2A0PC| Cpn01 Ppc 0<br />

View receptacle power status Esc 1PC W1PC| X5<br />

Set Executive mode on 1X 1X Exe 1<br />

Set Executive mode off 0X 0X Exe 0<br />

View Executive mode X X X5<br />

Power receptacle naming<br />

Set receptacle name24 Esc 1, X713 NO W 1%2C X713 NO | Nmo1, X713<br />

Set receptacle name to factory default24 Esc 1, NO W 1%2C%20NO | Nmo1, X713<br />

View receptacle name Esc 1NO W 1NO | X713<br />

Power receptacle scheduling<br />

Set scheduling24 Esc 1 * X711 * X5 * X712 SS W1%2A X711 %2A X5 %2A X712 SS | Sst 1* X711 X5 X712<br />

View scheduling Esc 1 * X711 * X5 SS W1%2A X711 %2A X5 SS | X712