Result — The RS-232 port is converted to a host port, which allows the use of SIS<br />

comm<strong>and</strong>s <strong>and</strong> host responses.<br />

No LEDs blink to indicate the mode switch. If the switch to mode 2 is<br />

successful <strong>and</strong> serial port communication is enabled, the interface screen<br />

displays one of the following the copyright messages:<br />

(c) Copyright 2007, <strong>Extron</strong> <strong>Electronics</strong>, IPL T PC1, Vx.xx, 60-544-xx<br />

(c) Copyright 2007, <strong>Extron</strong> <strong>Electronics</strong>, IPL T PC1i Vx.xx, 60-544-xx<br />

Purpose <strong>and</strong> notes — By default, the RS-232 is a device control port. In mode 2,<br />

the serial port is able to receive SIS comm<strong>and</strong>s.<br />

If you do not enter the three plus (+) signs within 2 seconds of the momentary<br />

press of the Reset button, the RS-232 port reverts to a device control port.<br />

Mode 3 (toggle event scripting on <strong>and</strong> off)<br />

Activation — Hold the Reset button in until the Power LED blinks one time (about<br />

3 seconds). Release it, then immediately press it again momentarily (for less<br />

than 1 second).<br />

Nothing happens if the momentary press does not occur within 1 second.<br />

Result — Turns events on or off, depending on their current state. During<br />

resetting, the reset LED flashes:<br />

Two times if events are starting<br />

Three times if events are stopping<br />

Purpose <strong>and</strong> notes — This mode is used for troubleshooting.<br />

Mode 4 (reset IP settings)<br />

Activation — Hold the Reset button in until the Power LED blinks two times<br />

(about 6 seconds). Release it, then immediately press it again momentarily<br />

(for less than 1 second). The Power LED blinks four times in quick<br />

succession, confirming a mode 4 reset.<br />

Nothing happens if the momentary press does not occur within 1 second.<br />

Result — Reset mode 4 does the following:<br />

Enables ARP program capability.<br />

Sets IP address back to factory IP settings.<br />

Sets Subnet address back to factory default.<br />

Sets Gateway address back to factory default.<br />

Sets port mapping back to factory default.<br />

Turns DHCP off.<br />

Turns events off.<br />

Purpose <strong>and</strong> notes — Mode 4 enables you to set IP address information using ARP<br />

<strong>and</strong> the MAC address without affecting any files on the unit.<br />

IPL T PC1 Front Panel Features <strong>and</strong> Operation<br />