Alarm input with N.O. (Normal Open) contact Alarm input with N.C. (Normal Closed) contact<br />
in idle state in idle state<br />
All settings are programmed in the ALARM menu (Section 0).<br />
1.8.2 Alarm Output Relay<br />
The relay output provides either Normally Open or Normally Closed dry contacts.<br />
Output relay in idle state<br />
1.9 RS-485 keyboard / PTZ Installation<br />
All functions can be remote-controlled by the EKB-500 universal keyboard. Using the EEPbus protocol,<br />
digital video recorders, keyboards and speed domes can be installed on one single RS-485 bus. One<br />
system can comprise up to 8 keyboards.<br />
1.9.1 General RS-485 bus installation<br />
The EKB-500 keyboard uses a RS-485 simplex wiring; the signal is transferred via a single twisted pair line.<br />
CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal applications. A<br />
shielded cable should be used if the installed cables are expected to be highly susceptible to interference.<br />
The number of devices installed in one bus is limited to 32, and the maximum cable length is 3,900 feet.<br />
Both of these can be expanded using a signal distributor EverFocus Model EDA997A (see below).<br />
Both the first and the last device in series should be terminated with 120 Ohm resistance in order to<br />
minimize line reflections.<br />
RS-485 bus serial wiring<br />
Cable length from box to device („Stubs“) has to be limited to 2m using connector boxes.<br />