Alarm input with N.O. (Normal Open) contact Alarm input with N.C. (Normal Closed) contact<br />

in idle state in idle state<br />

All settings are programmed in the ALARM menu (Section 0).<br />

1.8.2 Alarm Output Relay<br />

The relay output provides either Normally Open or Normally Closed dry contacts.<br />

Output relay in idle state<br />

1.9 RS-485 keyboard / PTZ Installation<br />

All functions can be remote-controlled by the EKB-500 universal keyboard. Using the EEPbus protocol,<br />

digital video recorders, keyboards and speed domes can be installed on one single RS-485 bus. One<br />

system can comprise up to 8 keyboards.<br />

1.9.1 General RS-485 bus installation<br />

The EKB-500 keyboard uses a RS-485 simplex wiring; the signal is transferred via a single twisted pair line.<br />

CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal applications. A<br />

shielded cable should be used if the installed cables are expected to be highly susceptible to interference.<br />

The number of devices installed in one bus is limited to 32, and the maximum cable length is 3,900 feet.<br />

Both of these can be expanded using a signal distributor EverFocus Model EDA997A (see below).<br />

Both the first and the last device in series should be terminated with 120 Ohm resistance in order to<br />

minimize line reflections.<br />

RS-485 bus serial wiring<br />

Cable length from box to device („Stubs“) has to be limited to 2m using connector boxes.<br />