EDR810H/EDR810M EDR410H/EDR410M - EverFocus
EDR810H/EDR810M EDR410H/EDR410M - EverFocus
EDR810H/EDR810M EDR410H/EDR410M - EverFocus
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
3. LOG:<br />
ON: Select ON if you wish to record Alarm Events in the Log.<br />
OFF: Select OFF if you do not wish to record Alarm Events in the Log.<br />
4. ACTIVE CAMERA: This field is to activate camera you want to have the alarm enabled too.<br />
For example if you had an external motion detector on camera one you would set this option to<br />
camera one. The Default from the factory is set to on. To change this, simply use the Jog Dial on<br />
the DVR.<br />
Active camera setting, from camera 01~08. You can set the camera which corresponds to<br />
the place where the alarm is located.<br />
Note: The recording camera number in an event depends on the alarm number, and the active<br />
camera images will not be recorded. Example: You assign camera 3 as the active camera to<br />
alarm 1. When the alarm 1 is triggered, camera 3 will be displayed and camera 1 will be<br />
recorded.<br />
5. PTZ PRESET: Select PTZ PRESET from “001” to “255”, so that when Alarm occurs, speed<br />
dome will turn to this preset position for event recording. This function improves surveillance<br />
quality of an alarm event. If you wish to disable this function, please simply select “OFF”.<br />
6. DURATION:<br />
1~99 SEC: The amount of time alarm recording, screen change, buzzer and output contact will<br />
last. Adjustable from 1 ~ 99 seconds.<br />
TRANSPARENT: Continuous recording, screen change, buzzer, and output contact for an alarm<br />
event.<br />
7. ALARM OUTPUT: This will transmit a signal to another device. The setting of alarms are<br />
NONE = not activated, 1 = output signal 1 transmitted.<br />
8. ALARM EMAIL:<br />
YES: Send an email when an alarm occurs.<br />
NO: Do not send an email when an alarm occurs.<br />
The email address and e-mail server can be set in the NETWORK SETUP MENU.<br />
9. BUZZER: Audible alarm buzzer.<br />
ENABLE: To enable an alarm buzzer.<br />
DISABLE: To disable an alarm buzzer.