when the APB property of a card is set as enabled and that card is presented<br />
twice consecutively on any enter-door reader or exit-door reader.<br />
The controller generates alarm output(s) according to the settings in the “APB<br />
Fail” column.<br />
• Card PIN Fail:<br />
A Card PIN Fail event is generated when a PIN-enabled card is presented at a<br />
reader and an incorrect PIN is entered three times consecutively.<br />
The controller generates alarm output(s) according to the settings in the “Card<br />
PIN error” column.<br />
• Door Forced Open:<br />
A Door Forced Open event is generated when the door sensor indicates to the<br />
controller that a door is opened, but no legitimate card has been presented and<br />
a request to exit has not been pressed.<br />
The controller generates alarm output(s) according to the settings in the<br />
“Forced Open” column.<br />
• Overtime:<br />
An overtime event occurs when a door is held open for longer than the allowed<br />
time (as set by the system administrator).<br />
The controller generates alarm output(s) according to the settings in the<br />
“Overtime” column.<br />
• Reader Lost:<br />
A Reader Lost event will be generated when controller detects that the card<br />
reader appears to have been disconnected from the system.<br />
The controller generates alarm output(s) according to the settings in the<br />
“Reader Lost” column.<br />
Configure an Alarm<br />
All the events can be allocated to any alarm relay output on main module, door module,<br />
and alarm module. The detailed configuration method is introduced in this section.<br />