All events that might trigger an alarm are listed and explained below. These events are<br />

located under the “Alarm setting 1”, “Alarm setting 2” and “Alarm setting 3” tabs in the<br />

<strong>Control</strong>ler Configuration window. How to set a particular alarm is explained in the next<br />

section, entitled “Configure a General Alarm”.<br />

Alarm Setting 1 Tab:<br />

Fig. 4.16 Alarm setting 1 tab<br />

Note: The content in Alarm setting tab will be only shown when the alarm module is<br />

installed in the controller.<br />

Alarm setting 1 tab shows the relationship between all the alarm outputs and the alarm<br />

inputs from Zone Alarm 1~8:<br />

The zone alarm reacts to 8 alarm inputs on the alarm module. The alarms are triggered<br />

according to the settings for each different Arm zone setting in the “ArmZone 1~8”<br />

columns.<br />

Alarm Setting 2 Tab:<br />

Alarm setting 2 tab shows the relationship between all the alarm outputs and the alarm<br />

inputs coming from the main module of Ever<strong>Access</strong> Flex controller, such as fire alarm<br />

and etc. All the alarm inputs are explained as below:<br />

• Fire Alarm:<br />

When a fire alarm input occurs, the controller generates a fire alarm output(s)<br />

according to the settings in the “Fire Alarm” column.<br />

• System PIN Fail:<br />

25