B) Toby <strong>Flexitemp</strong> Part Number MS10040<br />
Electrical oil valve control with the <strong>Flexitemp</strong>.<br />
1 2 3 4 5 6<br />
The <strong>Flexitemp</strong> allows the oil valve to be controlled automatically, and can be used to govern the firing rate of a<br />
stove with a boiler as illustrated in the two following drawings. High and low limit thermostats are incorporated<br />
to protect the boiler from condensation by not allowing it to run at too low a temperature and dissipating<br />
excess heat should the control thermostat fail. The high limit and control thermostat should be fitted at the<br />
boiler flow outlet and the low limit thermostat should be fitted to the boiler return inlet. All pipe thermostats<br />
must be fitted using heat conducting paste between the thermostat’s monitoring face and the pipe to ensure<br />
reliable thermal transmission. High temperature cables must be used to wire components in contact with or<br />
in close proximity to the stove. All wiring must be in accordance with whatever regulations may be applicable<br />
at the time of installation.<br />
Schematic electrical diagram for system with gravity D.H.W. and pumped space heating circuit.<br />
L<br />
N<br />
Pump<br />
1<br />
C<br />
90 C<br />
o<br />
2 1<br />
C<br />
2<br />
50 C<br />
o<br />
High Limit Low Limit<br />
Room<br />
Thermostat<br />
1 2 3 4 5 6<br />
<strong>Flexitemp</strong> unit.<br />
Control<br />
Thermostat<br />
Schematic electrical diagram for system with gravity D.H.W. and pumped space heating circuit, where no<br />
room thermostat is fitted.<br />
L<br />
N<br />
Pump<br />
1<br />
C<br />
90 C<br />
o<br />
2 1<br />
C<br />
2<br />
50 C<br />
o<br />
High Limit Low Limit<br />
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. 2004 6<br />
Operating <strong>Instructions</strong> Part number IN1051 Edition B<br />
1<br />
C<br />
2<br />
<strong>Flexitemp</strong> unit.<br />
1<br />
C<br />
2<br />
1 2 3 4 5 6<br />
Control<br />
Thermostat<br />
CH<br />
HW<br />
CH<br />
HW