B) Toby <strong>Flexitemp</strong> Part Number MS10040<br />

Electrical oil valve control with the <strong>Flexitemp</strong>.<br />

1 2 3 4 5 6<br />

The <strong>Flexitemp</strong> allows the oil valve to be controlled automatically, and can be used to govern the firing rate of a<br />

stove with a boiler as illustrated in the two following drawings. High and low limit thermostats are incorporated<br />

to protect the boiler from condensation by not allowing it to run at too low a temperature and dissipating<br />

excess heat should the control thermostat fail. The high limit and control thermostat should be fitted at the<br />

boiler flow outlet and the low limit thermostat should be fitted to the boiler return inlet. All pipe thermostats<br />

must be fitted using heat conducting paste between the thermostat’s monitoring face and the pipe to ensure<br />

reliable thermal transmission. High temperature cables must be used to wire components in contact with or<br />

in close proximity to the stove. All wiring must be in accordance with whatever regulations may be applicable<br />

at the time of installation.<br />

Schematic electrical diagram for system with gravity D.H.W. and pumped space heating circuit.<br />

L<br />

N<br />

Pump<br />

1<br />

C<br />

90 C<br />

o<br />

2 1<br />

C<br />

2<br />

50 C<br />

o<br />

High Limit Low Limit<br />

Room<br />

Thermostat<br />

1 2 3 4 5 6<br />

<strong>Flexitemp</strong> unit.<br />

Control<br />

Thermostat<br />

Schematic electrical diagram for system with gravity D.H.W. and pumped space heating circuit, where no<br />

room thermostat is fitted.<br />

L<br />

N<br />

Pump<br />

1<br />

C<br />

90 C<br />

o<br />

2 1<br />

C<br />

2<br />

50 C<br />

o<br />

High Limit Low Limit<br />

© EUROHEAT DISTRIBUTORS (H.B.S) LTD. 2004 6<br />

Operating <strong>Instructions</strong> Part number IN1051 Edition B<br />

1<br />

C<br />

2<br />

<strong>Flexitemp</strong> unit.<br />

1<br />

C<br />

2<br />

1 2 3 4 5 6<br />

Control<br />

Thermostat<br />

CH<br />

HW<br />

CH<br />

HW