Technical Specifi cation Bulletin Number<br />
Fuel Type Date of Issue E d i t i o n<br />
<strong>Oil</strong><br />
March 2004 1<br />
<strong>Oil</strong> <strong>Filter</strong> Fitting and <strong>Oil</strong> Direction<br />
<strong>TB177</strong><br />
Page Number<br />
The oil fi lter must be fi tted onto the fuel line so that the direction of the oil<br />
fl ow passing through the fi lter is as shown below.<br />
The direction of the oil fl ow<br />
The fi lter kit comes with brackets so that it may<br />
be securely fi tted to a wall. Where the oil fi lter<br />
mounting screw holes are facing a wall the small<br />
bracket should be used.<br />
See page 2 for details Diagram 2.<br />
Where the oil fi lter mounting screw holes are<br />
facing away from a wall the two brackets should<br />
be used.<br />
See page 2 for details Diagram 1.<br />
<strong>Euroheat</strong> Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom<br />
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100<br />
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk<br />
Latest Technical Information www.euroheat.co.uk/support<br />
1
Technical Specifi cation Bulletin Number<br />
Fuel Type Date of Issue E d i t i o n<br />
<strong>Oil</strong><br />
March 2004 1<br />
<strong>Oil</strong> <strong>Filter</strong> Fitting and <strong>Oil</strong> Direction<br />
Diag. 1 Diag. 2<br />
Wall<br />
<strong>Oil</strong> <strong>Filter</strong> Replacement<br />
When replacing the oil fi lter, which should be done<br />
annually, the new “O” rings supplied with the<br />
replacement fi lter must be used.<br />
Failure to do so can cause oil leaks and may allow air<br />
into the oil line which can effect the function of the<br />
oil control valve.<br />
The fi lter must then be bled of air by fi rst loosening<br />
the inlet bleed screw and then the outlet bleed<br />
screw.<br />
<strong>TB177</strong><br />
Wall<br />
<strong>Filter</strong> bleed screws<br />
CROSSLAND 489<br />
Page Number<br />
<strong>Euroheat</strong> Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom<br />
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100<br />
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk<br />