ENGLISH<br />
PROBLEM<br />
Fan not running,<br />
URSACHE:<br />
➧ Stove has no power supply.<br />
POSSIBLE SOLUTIONS:<br />
➧ Check that the stove plug is connected to<br />
the power supply. Ensure that the correct<br />
mains voltage is available at the wall plug.<br />
Caution: Remove mains plug!<br />
PROBLEM<br />
Soot or flue dust outside of the stove<br />
CAUSE(S):<br />
➧ Grate door open when stove is lit.<br />
➧ Leaks in the flue system or flue lines.<br />
POSSIBLE SOLUTIONS:<br />
➧ Always keep the grate door closed and if<br />
possible only open when the stove is not<br />
operating.<br />
➧ Rectify leaks in the extraction system<br />
(e.g. use heat resistant aluminium<br />
adhesive strip, heat resistant adhesive<br />
strip or heat resistant silicon).<br />
28<br />
CAUTION: checks must only be carried<br />
out on the control and cabling when no<br />
power is applied to the stove. Only trained<br />
personnel may carry out repairs.<br />
CONTROL OF ERROR MESSAGES<br />
If the stove does not stop according to the<br />
program (e.g. pellet container empty, over<br />
temperature triggered, lower temperature<br />
protection error message, air sensor fault,<br />
combustion fault (e.g. clogged combustion<br />
module, unsealed grate door, broken glass<br />
in grate door, etc) the error message “Err”<br />
(Error) appears on the display.<br />
When an error message occurs the corresponding<br />
cause must be rectified, the stove<br />
can then be re-started by pressing<br />
“ON/OFF”.