ENGLISH<br />

PROBLEM<br />

Fan not running,<br />

URSACHE:<br />

➧ Stove has no power supply.<br />

POSSIBLE SOLUTIONS:<br />

➧ Check that the stove plug is connected to<br />

the power supply. Ensure that the correct<br />

mains voltage is available at the wall plug.<br />

Caution: Remove mains plug!<br />

PROBLEM<br />

Soot or flue dust outside of the stove<br />

CAUSE(S):<br />

➧ Grate door open when stove is lit.<br />

➧ Leaks in the flue system or flue lines.<br />

POSSIBLE SOLUTIONS:<br />

➧ Always keep the grate door closed and if<br />

possible only open when the stove is not<br />

operating.<br />

➧ Rectify leaks in the extraction system<br />

(e.g. use heat resistant aluminium<br />

adhesive strip, heat resistant adhesive<br />

strip or heat resistant silicon).<br />

28<br />

CAUTION: checks must only be carried<br />

out on the control and cabling when no<br />

power is applied to the stove. Only trained<br />

personnel may carry out repairs.<br />

CONTROL OF ERROR MESSAGES<br />

If the stove does not stop according to the<br />

program (e.g. pellet container empty, over<br />

temperature triggered, lower temperature<br />

protection error message, air sensor fault,<br />

combustion fault (e.g. clogged combustion<br />

module, unsealed grate door, broken glass<br />

in grate door, etc) the error message “Err”<br />

(Error) appears on the display.<br />

When an error message occurs the corresponding<br />

cause must be rectified, the stove<br />

can then be re-started by pressing<br />

“ON/OFF”.