ENGLISH<br />

Fig 10<br />

Caution: Do not damage the flue fan<br />

during cleaning.<br />

CLEANING<br />

HOUSING<br />

THE FLUE GAS FAN<br />

This maintenance procedure should be carried<br />

out in accordance with stove operation<br />

and the fuel used.<br />

In order to inspect and clean the flue gas<br />

fan, remove the four hexagonal screws (Fig.<br />

5, 36) and carefully pull the flue fan motor<br />

(Fig. 5, 35) out of the housing. Remove the<br />

flue dust from the fan and flue gas outlets<br />

using a vacuum cleaner (Fig. 11). When closing<br />

ensure there are no leaks.<br />

Note: All motors have sealed ball bearings.<br />

Lubrication is not required.<br />

derlich.<br />

Fig 11<br />

CLEANING THE PELLET CONTAINER<br />

Do not fill the container up again immediately<br />

but remove residue (dust, chips etc.)<br />

from the empty container using a vacuum<br />

cleaner. (The stove must be disconnected<br />

from the power supply).<br />

26<br />

INSPECTING THE DOOR SEAL<br />

The state of the seals on the doors and<br />

glass should be checked at least once per<br />

year. Repair or replace the seal dependent<br />

on the state.<br />

CHECKING THE CHIMNEY CONNECTION<br />

Inspect and clean the connection. The collected<br />

flue dust can have a negative effect<br />

on the stove performance and represent a<br />

safety risk.<br />

CLEAN AIR SENSOR<br />

(Fig 12)<br />

The sensor must be serviced and cleaned<br />

by an authorised service technician.<br />

Clean with a soft brush.<br />

Ensure correct assembly (PCB must be<br />

below).<br />

Fig 12<br />

Air sensor