Graphical User Interface (GUI) Display Conventions<br />

<strong>Ion</strong> relies on many traditional <strong>ETC</strong> indicators which you may be familiar with, as well as some new<br />

ones. This section identifies the graphical and colorful conventions used in <strong>Ion</strong> to indicate<br />

conditions to you.<br />

Indicators in the Live/Blind Display<br />

This is the live/blind summary view.<br />

Note: The color and text conventions described below apply regardless of the format of<br />

live/blind being used (see Using [Format], page 43).<br />

Channel Number<br />

Straight line under<br />

channel heading<br />

Intensity data (I)<br />

Effect data<br />

No other parameter<br />

categories<br />

Wavy line under<br />

channel heading<br />

Intensity data (I)<br />

Focus data (F)<br />

Color data (C)<br />

Beam data (B)<br />

F, C, B icons<br />

when collapsed<br />

Conventionals<br />

Most of the channels in the above image are conventional<br />

channels (intensity is the only available parameter).<br />

Conventionals have a straight line beneath the channel<br />

number. They also display only the top field, intensity, as<br />

no other parameters are available on a conventional<br />

channel.<br />

Moving Lights or Multi-parameter Devices<br />

Several channels in the image are moving lights<br />

(possessing more parameters than just intensity).<br />

Moving light channels have a wavy line beneath the<br />

channel number as well as parameter category indicators<br />

at the bottom of the channel.<br />

This view also has additional data fields beneath intensity<br />

(F, C, B). This information can be suppressed by pressing<br />

and holding [Data] and any of the encoder paging keys<br />

(Focus, Color, Image, Shutter, or Form). Doing so will<br />

leave only the intensity field and FCB indicators at the<br />

bottom of the channel.<br />

3 System Basics 35