Change IP Address<br />

All <strong>Ion</strong> consoles by default have the same static IP address. All <strong>Ion</strong> RPUs also, by default, have the<br />

same static IP address.<br />

Default <strong>Ion</strong> Console IP Address: 10.101.100.101<br />

Default <strong>Ion</strong> RPU IP Address: 10.101.95.101<br />

Each <strong>Ion</strong> device on the network should be given a unique IP address. If running multiple devices of<br />

the same type (for example - two consoles, or two RPUs), you must alter the default static IP<br />

addresses to ensure proper functionality.<br />

Changing the static IP address is done through the ECU (see Network Settings, page 299), on the<br />

“Network” page. Manually change the IP address of any non-primary <strong>Ion</strong> device by clicking in the IP<br />

Address field and entering the new number from the keyboard. When done, press [Enter].<br />

Note:<br />

It is recommended that you alter the very last digit of the static IP address by an<br />

increment of one for each additional <strong>Ion</strong> device on the network. Therefore, if the<br />

master ends in “101”, change the backup to end in “102”, a client to end in “103”<br />

and so on.<br />