Set<br />

The “Set” command allows MSC to control potentiometers using both a numeric control number<br />

(which specifies the potentiometer) and a data field (which controls the level: 0-100). Control values<br />

are as follows:<br />

Accompanying any of these indications in the MSC data, a numeric value of 0-100 would set the<br />

specified potentiometer to that level.<br />

All other control values are ignored.<br />

Fire<br />

Control<br />

Value Indication<br />

1-127 Submaster 1-127<br />

128 Primary playback in<br />

129 Primary playback out<br />

510 Grandmaster<br />

This command fires a macro. MSC supports macros 1 through 127 only. Therefore a numeric value<br />

of 1 - 127 would accompany this command.<br />