Using Bump Button Timing With Submasters<br />

Each submaster bump can have three different timing values: Upfade, Dwell, and Downfade (see<br />

below). The default timing is set so that the bump functions as an “on” flash key for additive<br />

submasters and an “off” flash key for inhibitive submasters. Effects on submasters will follow<br />

submaster timing, unless timing has been placed in the effect itself<br />

The three timing values are:<br />

• Upfade time - this is the time for the submaster to fade from its home position to its target<br />

position (0 to Full if additive, Full to 0 if inhibitive). The default time is 0.<br />

• Dwell time - this is the time the submaster look will hold before starting the downfade. This<br />

can be set to a specified time, or to “Hold” or “Manual”. “H old” time maintains the submaster<br />

values until the bump is pressed a second time. “Manual” time applies the submaster values<br />

only as long as the bump is held. The default is “Manual”.<br />

• Downfade time - this is the time for the submaster to fade from its target position to its home<br />

position. The default time is 0.<br />

At any time, the potentiometer can be used to manually override fade progression or a submaster<br />

triggered with time.<br />

To add bump button timing live:<br />

• [Sub] [8] [Time] [3] [Time] [4] [Time] [3] [Enter] - adds a 3 second upfade, 4 second dwell<br />

and 3 second downfade to submaster 8.<br />

• [Sub] [4] [Time] [Time] {Manual} [Time] [3] [Enter] - adds a manual dwell time and a 3<br />

second downfade time to submaster 4. When the bump is pressed and held, it will flash on and<br />

stay on until the button is released, at which time it will begin the downfade.<br />

• [Sub] [4] [Time] [3] [Time] {Hold} [Enter] - adds a 3 second upfade time, and a ‘hold’ dwell<br />

time. When the bump is pressed, the upfade starts. Once at the target value it will remain there<br />

until the button is pressed again. The downfade will “bump” to zero.<br />

• [Sub] [4] [Time] [Enter] - resets all time for submaster 4 to default (Up = 0, Dwell = Manual,<br />

Down = 0).<br />

Controlling Subfades Manually<br />

It is possible to take control of submasters even if they have recorded time. To capture the fade you<br />

must push the potentiometer past the current fade level. Once this is done, control is transferred to<br />

the potentiometer for full manual control.<br />

You may then use the potentiometer to increase or decrease the submaster level as needed.<br />

21 Storing and Using Submasters 261