Using [Go To Cue] with Multiple Cue Lists<br />

[Go To Cue] defaults to the currently selected cue list. [Go to Cue] is a live function. It can not be<br />

used to change cues in blind. [Go to Cue] instructions can be executed from any operating mode,<br />

without returning to live.<br />

By default, a Go to Cue instruction is an out-of-sequence cue and will follow the rules of such (see<br />

Out-of-Sequence Cues, page 212).<br />

For examples of how to use [Go To Cue] in playback, please see Go To Cue, page 213.<br />

Using Go To Cue 0<br />

[Go To Cue] [0] is a command line instruction that resets all intensity values not owned by another<br />

fader to default, including any manual values that are not an override to another active fader value.<br />

[Go To Cue] [0] [Enter] also resets the selected cue list to the top of the list, with the first cue<br />

pending.<br />

To [Go To Cue] [0] on another cue list, press:<br />

• [Go To Cue] [2] [/] [0] [Enter]<br />

Note:<br />

Captured channels, independent values and values from other faders running a different cue list<br />

are not affected by a [Go To Cue] [0] command.<br />

When [Go To Cue] [0] is executed, any intensity values owned by the associated cue will fade out,<br />

while all non-intensity parameters remain in the current state. A [Go To Cue] [0] instruction does<br />

not impact the input from other programmers using partitioned control, unless the channels or<br />

parameters are shared.<br />

[Go To Cue] [0] & [Load]<br />

You can use the [Go To Cue] [0] button, located with the playback controls, in conjunction with a<br />

fader load button to send a specific cue list to cue 0. This action does not use the command line. On<br />

the desired fader, simply press:<br />

• [Go To Cue 0] & [Load]<br />

Using Go To Cue Out<br />

<strong>Ion</strong> has an added intensity parameter for LED fixtures, that by manufacturer<br />

default, have only RGB parameters but no intensity parameter. With this added<br />

control, the LED fixture will respond to the [Go To Cue] [0] command.<br />

To reset all parameters to their default state (unless they are controlled by a submaster) and reset<br />

all cue lists that are loaded to faders so that the first cue of each list is pending, press:<br />

• [Go To Cue] [Out] [Enter]<br />