Manual Timing at a Cue Level<br />

It is possible to assign a time of “manual”, for manual parameter transition through the associated<br />

fader. Manual times are assigned by using the {Manual} softkey that is displayed when recording<br />

a cue.<br />

• [Record] [4] [Time] {Manual} [Enter] - applies a manual time. If the cue had<br />

previously been given split times, would apply a manual to the upfade, focus, color, and beam<br />

times. If the cue had a single time, all of the timing would be “manual” and controlled by the<br />

fader.<br />

• [Record] [4] [Time] [Time] [Manual] [Enter] - applies a manual intensity time to the<br />

downfade.<br />

• [Record] [4] {Color} [Time] [Manual] [Enter] - applies a manual time to any color<br />

data changes in cue 4.<br />

Non-intensity Parameter Category Timing<br />

Timing can also be applied for focus, color, and beam parameter categories at a cue level. By<br />

default, FCB timing is the same as intensity upfade time. Once FCB timing is different than intensity<br />

upfade time, those times are no longer affected by intensity upfade changes.<br />

When you apply a time to an individual parameter category and that category has no movement,<br />

the time is displayed in grey. The specified timing will remain in grey until that category is provided<br />

with a move instruction, at which point it the timing will display in white.<br />

• [Record] [2] {Color} [Time] [7] [Enter] - records cue 2 with a cue level color time of 7.<br />

• [Record] [2] {Color} [Time] [Enter] - resets the color time of cue 2 back to the default<br />

value.<br />

• [Record] [2] [Time] [Time] [Time] [7] [Enter] - records cue 2 with a cue level focus<br />

time of 7. In this example, each press of the [Time] key steps through each timing value (up<br />

time, down time, focus time, color time and beam time.<br />

• [Record] [2] [Time] [7] [Enter]- records cue 2 and puts a time of 7 on all parameter<br />

categories (if FCB all had the same times to begin with).<br />

Note:<br />

It is not necessary to rerecord a cue to alter stored timing data. You can simply<br />

redefine the time by specifying the cue and re-entering the time value(s).<br />

• [Cue] [5] [Time] [8] [Enter] - Redefines the all category times to 8<br />

seconds (If FCB all had the same timing).<br />

• [Cue] [2] {Color} [Time] [5] [Enter] - Redefines color time to 5<br />

seconds.<br />

• [Cue] [3] {Focus} [Time] [-] [2] [Enter] - Removes 2 seconds from<br />

the current time.<br />

• [Cue] [7] {Beam} [Time] [+] [3] [Enter] - Adds 3 seconds to the<br />

current time.<br />