Using Record Only<br />

[Record Only] is similar to [Record] except that it selectively stores only manually set values,<br />

preventing unwanted levels (such as from a submaster or another cue list), from being recorded<br />

into the cue. Therefore, when used to record a cue, only the manual data for channels will be stored<br />

in the cue. Any values in the previous cue that were unchanged will track into the new cue.<br />

All of the same commands used for [Record] may also be used for [Record Only].<br />

• [Record Only] [Next] [Enter] - stores only the manually set values into the next cue<br />

in the list.<br />

• [Record Only] [Cue] [3] [Enter] - stores only the manually set data into cue 3.<br />

• [2] [thru] [8] [Record Only] [9] [Enter] - stores only the manually set data for<br />

channels 2 through 8 into the target cue 9.<br />

• [Group] [2] [Record Only] [Cue] [5] [Enter]- stores only the manual data from group 2 into<br />

cue 5.<br />

• [selected channels] {Color} [Record Only] [4] [Enter] - stores only the color data for<br />

the selected channels into cue 4.<br />

As with [Record], filters can further restrict stored data if deployed when using [Record Only]. See<br />

“Using Filters” on page 183.<br />