Editing Palettes in Blind<br />

CAUTION:<br />

Palettes can be viewed and edited in blind in the table and spreadsheet views.<br />

Entering Blind Palette from Live<br />

• [Blind] & [Palette] - pressing this will display the first recorded palette of the selected type<br />

(Intensity, Focus, Color or Beam) in blind or return to the last palette of this type viewed in<br />

blind.<br />

• [Blind] {Palette Select 1} or [Blind] [Palette] [1] [Enter] - pressing this will display the<br />

specified palette “1” in blind.<br />

• [Palette] [Palette] {Edit} - opens the list view of the palette type and then opens blind palette.<br />

View palettes from blind<br />

While in any blind mode, when no channels are selected, you can enter a palette from the<br />

command line or direct selects. This will take you into blind channel mode for that palette.<br />

• [Color Palette] [n] [Enter]<br />

You may also cycle through the available palettes using [Next] and [Last].<br />

Editing in Blind<br />

The following are representative methods used for editing palettes in blind:<br />

• [2] {Iris} [At] [Enter] - removes the current parameter category setting from channel 2.<br />

• [1] {Iris} [5] [0] [Enter] - selects channel 1 and sets iris value to 50.<br />

• [2] [Copy To] [5] [Enter]- copies the information from channel 2 to channel 5.<br />

• [6] [Recall From] [Focus Palette] [1] [Enter] - recalls the values for channel 6 from Focus<br />

Palette 1.<br />

You may use the encoders to set blind levels as well.<br />

When editing in blind, it is possible to remove an instruction from any palette by selecting the<br />

channel and parameter and pressing [At] [Enter] or {Make Null} [Enter].<br />

[Recall From], [Copy To], {Replace With}, and {Move To} may be used to create and edit palette<br />

data. See Advanced Manual Control, page 195.<br />

Note:<br />

.<br />

When editing palettes in blind, changes to palettes are automatic, therefore no<br />

update or record command is required.<br />

While editing palettes in blind, hitting [Recall From][Recall From] will put [Recall<br />

From][Palette] on the command line.<br />