Selective Storing Palettes with [Record]<br />

Palettes can also be created using selective storing, which allows you to specify only the channels<br />

and or parameters that you want to store.<br />

The following examples illustrate various methods of selectively storing palettes using [Record]:<br />

• [1] [thru] [3] [Record] [Intensity Palette] [2] [Label] [Enter] - records the intensity<br />

data for selected channels 1 through 3 and adds a label to intensity palette 2.<br />

• [Group] [2] [Record] [Beam Palette] [Next] [Enter] - records the beam parameter data for<br />

Group 2 to the next sequential beam palette number.<br />

• [-] [9] [Record] [Focus Palette] [5] [Enter] - stores the focus data to focus palette 5,<br />

excluding the group or channels specified.<br />

• [1] [Thru] [9] {Iris} {Zoom} [Record] [Beam Palette] [5] [Enter] - stores all zoom and iris<br />

data for channels 1-9 to beam palette 5.<br />

Note:<br />

When using a selective store, you must specify the channel list to be included or<br />

excluded, identified by the [+] [-] modifier, as part of the [Record] command.<br />

Otherwise all channels with appropriate non-default data will be stored in the new<br />

palette.<br />

Also, selective storing is useful when you are doing a “one-time” selective store<br />

action. If you are recording a series of palettes with only specific parameters, it will<br />

save you time to set a record filter (see Using Filters with Palettes, page 141).<br />

Storing Palettes with [Record Only]<br />

[Record Only] is a selective record process that stores only manual parameter data. When used to<br />

record palettes, only the manual parameter data for channels will be stored in the palette. As with<br />

record, filters can further restrict stored data if they are enabled when using [Record Only]. See<br />

“Storing Palettes Live” on page 139.<br />

Note:<br />

If you use [Record Only] to record to an existing palette, the data will be added<br />

to that palette. The original palette will not be completely overwritten. Only manual<br />

changes will be stored to the palette.<br />

It is also possible to [Update] to add specific changes to the record target. See<br />

“Editing Palettes Live” on page 143.<br />

The following methods can be used to selectively store manual parameter data to palettes using<br />

[Record Only]:<br />

• [Record Only] [Color Palette] [2] [Enter]- records only the manual color parameter data to<br />

color palette 2.<br />

• [Record Only] [Beam Palette] [5] [Label] [Enter] - records manual beam<br />

parameter data for all channels and adds a label to beam palette 5.<br />

• [-] [9] [Record Only] [Color Palette] [Next] [Label] [Enter] - stores to the next<br />

sequential color palette, withholding the group or channels specified and adds a label.<br />

• [select channels] [Record Only] [Focus Palette] [2] [Enter] - stores focus palette 2, but only<br />

includes the manual data for the specified channels and parameters.<br />

• [1] [Thru] [9] {Iris} {Zoom} [Record Only] [Beam Palette] [5] [Enter] - stores only manual<br />

zoom and iris data for channels 1-9 to beam palette 5.<br />