Multiple Intensity Channels<br />

When a multiple intensity channel is patched, <strong>Ion</strong> assigns it a master intensity. The master intensity<br />

can be used to control the multiple intensities together. The master intensity is handled in the same<br />

way as the intensity of a single intensity channel. Levels can be set via the level wheel, from the<br />

keypad, and the encoders. Master intensity can also be set via the parameter buttons in the CIA.<br />

{Intens} controls the master intensity. The other intensities will default to 100%.<br />

Control of the individual intensities of a multiple intensity channel is handled using keypad with the<br />

parameter buttons in the CIA (see Manual Control of Non-intensity Parameters (NPs), page 111) or<br />

the encoders. Pressing the [Custom] button will map the intensity parameters to the encoders. You<br />

can either use the encoder itself to adjust the level or you can press down the encoder of the<br />

parameter you wish to put on the command line.<br />

Levels assigned to the individual intensities will act independent of each other and the master<br />

intensity.<br />

• [1][0][0] {Intens 3} [At] [5][0] - sets intensity 3 of channel 100 to 50% intensity.<br />

• [1][0][0] [At] [7][5] - sets the master intensity of channel 100 to 75% intensity. All<br />

intensities for channel 100 will be set to 75% unless they have a separate intensity set.<br />

In Table view, <strong>Ion</strong> will default to showing all intensity parameters associated with the channels.<br />

In summary view, the master intensity is shown. If one of the<br />

multiple intensities has a value, an ‘+’ will display beside the<br />

master intensity.<br />

indicates that<br />

there is a level<br />

set from an<br />

individual<br />

intensity<br />

120 <strong>Ion</strong> Operations Manual