<strong>Ion</strong> is equipped with a [Home] hardkey. This hardkey allows you to home a specific parameter.<br />

Additionally, you may home all of a channel’s non-intensity parameters or home only a specific<br />

category (I, F, C, B).<br />

Homing a channel, category, parameter, or submasters will return it to the default value.<br />

• [1] [Home] [Enter] - homes all parameters for channel 1, except intensity.<br />

• [1] [Color] [Home] [Enter] - homes all color parameters for channel 1.<br />

• [Group] [1] [Color] [Focus] [Home] [Enter] - homes the color and focus parameters of all<br />

channels in group 1. You can use the category keys in the CIA or the encoder paging keys.<br />

• [Sub] [1] [Home] [Enter] - homes submaster 1.<br />

• [Sub] [1] [Thru] [Home] [Enter] - homes all submasters.<br />

You can select a preset to provide home values for non-intensity parameters (instead of fixture<br />

library default values) when home commands are used. Store a preset with modified home values<br />

for only the channel parameters you would like at a different value than default. And then assign<br />

that preset to Home in Setup (see Show Settings, page 95). Intensity will disregard the preset<br />

value. Any channels that are not included in the preset assigned to Home in Setup will use their<br />

library defaults.<br />

Select Last<br />

The [Select Last] key allows you to reselect the previous channel selection. This includes multiple<br />

channel selections, groups, and so on. Using [Select Last] [Select Last] you can recall the last<br />

completed command line. However [Select Last] [Select Last] will not terminate the command<br />

line, [Enter] is required.<br />

When pressed and held, the softkeys on <strong>Ion</strong> change to display the following additional options:<br />

• {Select Active} - selects all active channels.<br />

• {Select Manual} - selects all channels with manual data.<br />

• {Select All} - selects all channels.<br />

8 Basic Manual Control 119