Manual Control of Non-intensity Parameters (NPs)<br />

Non-intensity parameters can be set with a variety of controls including the control keypad, buttons<br />

on the central information area (CIA) and the encoders.<br />

Parameter Display<br />

The parameter display in the CIA is populated with only those parameters that are found in the<br />

patched devices. As channels are selected, the parameter display will change to show only<br />

parameters relevant to the selected channels.<br />

The parameters are divided into the following categories: Intensity, Focus, Color and Beam. Each<br />

parameter category is represented with buttons at the bottom of the CIA. These buttons allow you<br />

to select the entire collection of all parameters within that category in one button press. You can<br />

also select a single parameter from a category using that parameter’s button in the parameter<br />

display.<br />

Beam has three subcategories which correspond to the way the encoders are mapped. They are<br />

{Shutter}, {Image}, and {Form}. These subcategories are represented with buttons in the CIA.<br />

Pressing these buttons allows you to select all parameters within those subcategories.<br />

Within the CIA, in the upper left corner, notice the {All NPs} button. When pressed, this collects all<br />

non-intensity parameters for further editing.<br />

Some examples of using parameter buttons are:<br />

• [1] {Iris} [5] [Enter] - Places the iris parameter of channel 1at 50%.<br />

• [Group] [4] {Zoom} {Edge} [Out] [Enter] - Sends any zoom and edge values for all fixtures<br />