Show Control<br />

This section allows you to adjust settings for MIDI show control, time code (MIDI or SMPTE),<br />

analog, and serial functions<br />

{SMPTE Time Code Rx}<br />

This touchbutton is used to toggle SMPTE time code between “Enabled” and “Disabled”, thereby<br />

controlling whether <strong>Ion</strong> can receive SMPTE time code. Choosing “Disabled” will disable all<br />

timecode lists that have a SMPTE source. The default for this setting is “Enabled”.<br />

{MIDI Time Code Rx}<br />

As above, but for MIDI instead of SMPTE. The default for this setting is “Enabled”.<br />

{Resync Frames}<br />

This touchbutton allows you to configure how many frames need to be synced before timecode<br />

starts running. Frames can be from 1-30. Default is 2 frames.<br />

{MSC Receive}<br />

This touchbutton toggles the setting for receiving MIDI Show Control from an external source<br />

between “Enabled” and “Disabled”. The default setting is “Disabled”.<br />

{MSC Receive Channel}<br />

Also known as "Device ID" this setting allows you to establish the MIDI Show Control device ID for<br />

<strong>Ion</strong>. The device ID can be set from 0-126. <strong>Ion</strong> will process commands sent to the matching Device<br />

Id. <strong>Ion</strong> will also process commands sent to Device Id 127 (All Call). For example:<br />

• {MSC Receive Channel} [5] [0] [Enter]<br />

{ACN - MIDI Rx ID(s)}<br />

This setting allows you to specify the MIDI Show Control data that <strong>Ion</strong> will receive when transmitted<br />

over the Advanced Control Network (ACN). When set, <strong>Ion</strong> will receive MSC data from any gateway<br />

that has its “MIDI In Stream ID” set to the same number. ACN_MIDI Receive ID can be from 1-32.<br />

ID ranges may be used. For example:<br />

• {ACN_MIDI Receive ID} [2] [5] [Enter]<br />

{MSC Transmit}<br />

This touchbutton toggles the setting for transmitting MIDI Show Control data between “Enabled”<br />

and “Disabled”. The default setting is “Disabled”.<br />

{MSC Transmit Channel}<br />

Also know as "Device ID" this setting allows you to establish the device ID with which <strong>Ion</strong> will<br />

transmit MIDI show control information. A device ID can be from 0-126 or 127 (All Call). For<br />

example:<br />

• {MSC Transmit Channel} [5] [0] [Enter]<br />

98 <strong>Ion</strong> Operations Manual