Leaky pipes, valves or ducts also require more power to deliver the same volume needed.<br />

Filters <strong>and</strong> fan belts should be replaced at the appropriate times to ensure efficient energy<br />

consumption.<br />

The pump or fan curve should be properly matched to the load curve.<br />

Right-sizing of pumps <strong>and</strong> fans to match the load is important in implementing energy<br />

efficiency.<br />

Technical knowledge <strong>and</strong> operations <strong>and</strong> maintenance skills on fans <strong>and</strong> pumps in industry<br />

<strong>and</strong> commerce are essential to the successful delivery of energy efficiency.<br />

Avoid fan belt slippage - replace if worn<br />

While working in your office use daylight instead of electric light as far as possible.<br />

HVAC<br />

Evaluate night setback control against dynamic control.<br />

Relate chilled water temperature to building load.<br />

Reduce warm fresh air intake to an acceptable limit <strong>and</strong> recycle colder inside air.<br />

Use the cold outside air during the night to cool the building (free cooling).<br />

Switch off non-essential electrical loads during the night.<br />

Electricity is also wasted by the HVAC system in overcoming this temperature build up.<br />

Industrial<br />

Appendices continued...<br />

Switch off any drive that is running when it is not adding value to the operation for which it<br />

was intended.<br />

Use electricity efficient motors<br />

Replace efficient motors rather than rewinding them<br />

Upgrade to higher efficiency motors<br />

Evaluate pump <strong>and</strong> fan systems regularly to check for leaks <strong>and</strong> proper placement<br />

Assure thorough maintenance of systems<br />

Replace fan belts <strong>and</strong> filters at the appropriate times<br />

Match the pump of <strong>and</strong> fan curve to the load curve<br />

Ensure the right-sizing of pumps <strong>and</strong> fans match<br />

the load<br />

Consider alternatives to conventional pumping<br />

where feasible<br />

Check conditions of fan belts<br />