24.08.2013 Views

M&V Solar Water Heating Guideline - Eskom

M&V Solar Water Heating Guideline - Eskom

M&V Solar Water Heating Guideline - Eskom

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Measurement and Verification Standard <strong>Guideline</strong> for Low Pressure <strong>Solar</strong> <strong>Water</strong> <strong>Heating</strong> Systems v1r1<br />

Figure 21: A Hobo Data Logger installed at a DB in a Low-cost House to determine the base<br />

line and energy savings by the retrofit.<br />

It should be noted that, the field measurements after the retrofit will be misleading when<br />

taken after the installations of the LPSWHs. This is due to the fact that the households could<br />

use the electricity for other applications such as : refrigeration, entertainment etc.(in the<br />

same manner as in the CFL rollouts) and the fact that some hot water usages has been<br />

replaced by the LPSWH. On the other hand people get used to utilize hot water for different<br />

applications after the retrofit.<br />

6.4.5 Recommendations for Baseline Procedure<br />

The following methodology is recommended as a Standard <strong>Guideline</strong> for Baseline<br />

development for Low Pressure <strong>Solar</strong> <strong>Water</strong> <strong>Heating</strong> Systems:<br />

Perform interviews and fill the information as required in Fieldworker Form [6]. A<br />

typical form is shown at the worked example shown in Section 10.<br />

Identify representative houses in terms of number and profile of occupants and<br />

install data loggers (if and where appropriate ) to measure the electricity<br />

consumption prior the retrofit.<br />

Determine electrical energy and find out the time of its use for water heating,<br />

based on the information obtain above .<br />

7 DETERMINATION OF THE SAVINGS<br />