<strong>Load</strong> <strong>set</strong> <strong>calculation</strong> DOWEC 6MW H. Efdé<br />

4 Results<br />

After the PhatasIV <strong>calculation</strong>s the digital output files were converted in ASCI format with the Phatas<br />

postprocessor PHPOST.exe. PHPOST can convert 128 variables maximum per postprocessing run.<br />

Stentec B.V.’s post processor ADAP was used to generate extreme values tables, statistics and for<br />

fatigue analysis 1Hz equivalent signals. The extreme values were extracted from all load cases of<br />

the ulitmate and fatigue load <strong>set</strong>. For the fatigue analysis only load cases 12 a/b, 18a/b and 24a/b<br />

were examined. These are considered to be the decisive load cases for optimalisation.<br />

4.1 Maximum tower foot bending moment<br />

According IEC 6.1 36 simulations are performed with the wind turbine idling at a windspeed<br />

(stochastic model) of 41.5 m/s. Each load case is calculated with a different wind direction. To<br />

improve the idling of the model, the pitch angle of the blades is <strong>set</strong> at 85º.<br />

The maximum resulting tower foot bending moments are:<br />

Table 8: Ultimate tower foot bending moments<br />

Variable Extreme Ldcase 2 Ldcase 3 Ldcase 4 Ldcase<br />

Mxt[01] -177230 E50335 -158310 E50325 -155300 E50345 -139370 E50315<br />

Myt[01] 79498 E50025 -79262 E50175 -76273 E50185 -74108 E50195<br />

all values in kNm, load factor = 1.00<br />

The load case E50335 generates the highest tower foot bending moment. This load case is repeated<br />

8 times, but for each load case a different stochastic model is used. The maximum tower bending<br />

moments are:<br />

Table 9: Ultimate tower foot bending moments<br />

Variable 1 2 3 4 5 6 7 8<br />

Mxt[01] -177230 -170690 -166180 -147640 -146740 -135330 -133620 -117230<br />

Myt[01] 87609 85477 77240 73366 71669 67842 65646 53084<br />

all values in kNm, load factor ¡ = 1.00<br />

From these values it can be determined that the mean maximum tower foot bending moment<br />

Mxt[01] is: 149333 kNm.<br />

It has to be noted that this value is not the absolute highest value. When looking at the extreme<br />

values tables load case GrEog1Voc generates the highest tower foot bending moment Myt[01],<br />

which is -281560 kNm (with ¢ = 1.00) . For a plot of this loadcase see Appendix C.<br />

R45.04/01.03/03 Stentec, 3-1-03 page 11