CLASSIC G HS (PDF) - ARC Laser
CLASSIC G HS (PDF) - ARC Laser CLASSIC G HS (PDF) - ARC Laser
CLASSIC G HS & K T P 532 nm Coagulation with a reliable KTP system
<strong>CLASSIC</strong> G<br />
<strong>HS</strong> & K T P 532 nm<br />
Coagulation with a reliable<br />
KTP system
FEATURES<br />
KTP optical attachement:<br />
Uncompromising and reliable.<br />
<strong>Laser</strong> body and console<br />
A.R.C. <strong>Laser</strong> GmbH<br />
Bessemerstraße 14<br />
D-90411 Nürnberg<br />
Germany<br />
Coagulation with a reliable<br />
KTP system<br />
Coagulation with the <strong>CLASSIC</strong> G<br />
The A.R.C. <strong>Laser</strong> Classic and Classic G laser attachments are<br />
directly attached to the slit illumination via a “swing in-swing out”<br />
mirror in the illumination tower of the BQ slit lamp.<br />
Consequently, there is no color change in the slit illumination. In<br />
addition, as the last mirror of the slit lamp is not hindered by attachments,<br />
the operator can perform standard contact lens examinations<br />
in a normal manner.<br />
OPTIONAL: The superior design allows to attach a tonometer<br />
to the axis of the slit lamp. If required, the laser attachment coupling<br />
to the illumination tower can easily be removed by sliding<br />
the laser mirror to the side. The Q-LAS Photodisruptor and<br />
video camera may also be adapted to this slit lamp.<br />
SPECIFICATIONS <strong>CLASSIC</strong> G<br />
<strong>Laser</strong>, wavelength Diode pumped YAG, 532 nm<br />
Output power > 2 W at fiber and 1.2 W at cornea<br />
Spot size 50 to 500 µ, zoom optic<br />
Aiming beam <strong>Laser</strong> diode 635 nm, red<br />
with adjustable intensity<br />
Adaptation Haag Streit BQ<br />
Repetition rates 1 to 5 Hz<br />
µ Manipulator Electric at last mirror<br />
Weight 12 kg<br />
Dimensions 465 x 181 x 267 mm<br />
� +49 (0) 911 217 79 -0<br />
� +49 (0) 911 217 79 99<br />
info@arclaser.de<br />
www.arclaser.de<br />
Technical data is subject to change without notice.<br />
VISIBLE AND INVISIBLE LASER RADIATION<br />
AVOID EYE OR SKIN EXPOSURE TO<br />
DIRECT OR SCATTERED RADIATION<br />
KTP LASER 532 nm = 3 Watt CW<br />
Nd:YAG LASER 1064 nm = 30 mJ Pulse<br />
DIODE LASER 635 nm = < 5 mW CW<br />
Your local distributor:<br />
LASER RADIATION<br />
avoid exposure to beam<br />
CLASS 4 LASER PRODUCT<br />
532 nm, P < 5 Watt<br />
635 nm, P < 5 mW<br />
A.R.C. <strong>Laser</strong> certifies that the product complies to 21 CFR 1040.10 and 1040.11 EN 13485/ 2003 - 93/42 EWG