CLASSIC G HS (PDF) - ARC Laser

CLASSIC G HS (PDF) - ARC Laser CLASSIC G HS (PDF) - ARC Laser

<strong>CLASSIC</strong> G<br />

<strong>HS</strong> & K T P 532 nm<br />

Coagulation with a reliable<br />

KTP system


FEATURES<br />

KTP optical attachement:<br />

Uncompromising and reliable.<br />

<strong>Laser</strong> body and console<br />

A.R.C. <strong>Laser</strong> GmbH<br />

Bessemerstraße 14<br />

D-90411 Nürnberg<br />

Germany<br />

Coagulation with a reliable<br />

KTP system<br />

Coagulation with the <strong>CLASSIC</strong> G<br />

The A.R.C. <strong>Laser</strong> Classic and Classic G laser attachments are<br />

directly attached to the slit illumination via a “swing in-swing out”<br />

mirror in the illumination tower of the BQ slit lamp.<br />

Consequently, there is no color change in the slit illumination. In<br />

addition, as the last mirror of the slit lamp is not hindered by attachments,<br />

the operator can perform standard contact lens examinations<br />

in a normal manner.<br />

OPTIONAL: The superior design allows to attach a tonometer<br />

to the axis of the slit lamp. If required, the laser attachment coupling<br />

to the illumination tower can easily be removed by sliding<br />

the laser mirror to the side. The Q-LAS Photodisruptor and<br />

video camera may also be adapted to this slit lamp.<br />

SPECIFICATIONS <strong>CLASSIC</strong> G<br />

<strong>Laser</strong>, wavelength Diode pumped YAG, 532 nm<br />

Output power > 2 W at fiber and 1.2 W at cornea<br />

Spot size 50 to 500 µ, zoom optic<br />

Aiming beam <strong>Laser</strong> diode 635 nm, red<br />

with adjustable intensity<br />

Adaptation Haag Streit BQ<br />

Repetition rates 1 to 5 Hz<br />

µ Manipulator Electric at last mirror<br />

Weight 12 kg<br />

Dimensions 465 x 181 x 267 mm<br />

� +49 (0) 911 217 79 -0<br />

� +49 (0) 911 217 79 99<br />

info@arclaser.de<br />

www.arclaser.de<br />

Technical data is subject to change without notice.<br />

VISIBLE AND INVISIBLE LASER RADIATION<br />

AVOID EYE OR SKIN EXPOSURE TO<br />

DIRECT OR SCATTERED RADIATION<br />

KTP LASER 532 nm = 3 Watt CW<br />

Nd:YAG LASER 1064 nm = 30 mJ Pulse<br />

DIODE LASER 635 nm = < 5 mW CW<br />

Your local distributor:<br />

LASER RADIATION<br />

avoid exposure to beam<br />

CLASS 4 LASER PRODUCT<br />

532 nm, P < 5 Watt<br />

635 nm, P < 5 mW<br />

A.R.C. <strong>Laser</strong> certifies that the product complies to 21 CFR 1040.10 and 1040.11 EN 13485/ 2003 - 93/42 EWG