<strong>LTC</strong> <strong>Repair</strong> Electrical <strong>Troubleshooting</strong><br />
6.18 Lights do not Illuminate—Flowchart 1C<br />
Check voltage at the main circuit breaker.<br />
See Checking Voltage at the Main Circuit Breaker.<br />
Check incoming voltage<br />
to ballast capacitors.<br />
Is 240V±10%<br />
measured?<br />
No<br />
<strong>Repair</strong> wiring<br />
between short<br />
terminal strip and<br />
main circuit<br />
breaker.<br />
See Checking Incoming<br />
Voltage to Ballast Capacitor(s).<br />
Is 400±10%V<br />
measured?<br />
Yes<br />
Check outgoing voltage<br />
from ballast capacitors.<br />
See Checking Outgoing<br />
Voltage from Ballast Capacitors.<br />
Is 400V±10%<br />
measured?<br />
No<br />
Replace<br />
ballast capacitor(s).<br />
No<br />
Yes<br />
Yes<br />
<strong>Repair</strong> wiring<br />
between main<br />
circuit breaker and<br />
long terminal<br />
strip.<br />
<strong>Repair</strong> wiring<br />
between individual<br />
circuit breakers and<br />
ballast capacitors<br />
and/or replace<br />
transformer (s).<br />
97<br />
Check voltage at the long terminal strip.<br />
See Checking Voltage to Long Terminal Strip.<br />
No<br />
Is 230±10%V<br />
measured?<br />
Yes<br />
Check voltage at individual circuit breakers.<br />
See Checking Individual Circuit Breakers.<br />
Yes<br />
Conduct continuity tests on<br />
the wiring between the ballast capacitors<br />
and the mast junction box. <strong>Repair</strong> or<br />
replace the wiring as needed.<br />
Is 230V±10%<br />
measured?<br />
No<br />
<strong>Repair</strong> wiring<br />
between long<br />
terminal strip and<br />
individual circuit<br />
breakers and/or<br />
replace circuit<br />
breaker(s).<br />
wc_gr003814