21.08.2013 Views

LTC Repair Lombardini Engine Troubleshooting - Wacker Neuson

LTC Repair Lombardini Engine Troubleshooting - Wacker Neuson

LTC Repair Lombardini Engine Troubleshooting - Wacker Neuson

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>LTC</strong> <strong>Repair</strong> Electrical <strong>Troubleshooting</strong><br />

6.18 Lights do not Illuminate—Flowchart 1C<br />

Check voltage at the main circuit breaker.<br />

See Checking Voltage at the Main Circuit Breaker.<br />

Check incoming voltage<br />

to ballast capacitors.<br />

Is 240V±10%<br />

measured?<br />

No<br />

<strong>Repair</strong> wiring<br />

between short<br />

terminal strip and<br />

main circuit<br />

breaker.<br />

See Checking Incoming<br />

Voltage to Ballast Capacitor(s).<br />

Is 400±10%V<br />

measured?<br />

Yes<br />

Check outgoing voltage<br />

from ballast capacitors.<br />

See Checking Outgoing<br />

Voltage from Ballast Capacitors.<br />

Is 400V±10%<br />

measured?<br />

No<br />

Replace<br />

ballast capacitor(s).<br />

No<br />

Yes<br />

Yes<br />

<strong>Repair</strong> wiring<br />

between main<br />

circuit breaker and<br />

long terminal<br />

strip.<br />

<strong>Repair</strong> wiring<br />

between individual<br />

circuit breakers and<br />

ballast capacitors<br />

and/or replace<br />

transformer (s).<br />

97<br />

Check voltage at the long terminal strip.<br />

See Checking Voltage to Long Terminal Strip.<br />

No<br />

Is 230±10%V<br />

measured?<br />

Yes<br />

Check voltage at individual circuit breakers.<br />

See Checking Individual Circuit Breakers.<br />

Yes<br />

Conduct continuity tests on<br />

the wiring between the ballast capacitors<br />

and the mast junction box. <strong>Repair</strong> or<br />

replace the wiring as needed.<br />

Is 230V±10%<br />

measured?<br />

No<br />

<strong>Repair</strong> wiring<br />

between long<br />

terminal strip and<br />

individual circuit<br />

breakers and/or<br />

replace circuit<br />

breaker(s).<br />

wc_gr003814