Maintenance <strong>LTC</strong> <strong>Repair</strong><br />
4. Maintenance<br />
4.1 Periodic Maintenance Schedule<br />
38<br />
Before<br />
each<br />
use<br />
Check for fluid leaks. <br />
Check engine oil. <br />
Check fuel level. <br />
Replace air filter if indicator light is on.** <br />
Every<br />
125<br />
hours<br />
Change engine oil.* <br />
Check level of battery electrolyte. <br />
Every<br />
250<br />
hours<br />
Check condition and tension on fan belt. <br />
Check condition of radiator hoses. <br />
Replace oil filter.* <br />
Replace fuel filter. <br />
Flush radiator. <br />
Replace fan belt. <br />
Check valve clearance. <br />
Every<br />
500<br />
hours<br />
Every<br />
1000 hours<br />
or two years<br />
Remove sediment in fuel tank. <br />
Change radiator coolant. <br />
Replace battery. <br />
Replace radiator hoses and clamps. <br />
Replace fuel pipes and clamps. <br />
* Change engine oil and filter after first 50 hours of operation.<br />
** Replace air filter after air filter restriction switch indication or one year. <strong>Lombardini</strong> does not<br />