Electrical <strong>Troubleshooting</strong> Procedures <strong>LTC</strong> <strong>Repair</strong><br />
6.29 Checking Receptacle’s Circuit Breaker<br />
See Graphic: wc_gr003081<br />
WARNING<br />
Electric shock hazard. Only qualified personnel should conduct this<br />
test.<br />
Complete this test with the machine running.<br />
6.29.1 Using the AC voltage setting on the multimeter, measure the incoming<br />
voltage to the receptacle’s circuit breaker by measuring between the<br />
brown-yellow wire (a) and the wires (b) of the terminal strip. There<br />
should be 115V or 230V±10% depending on model.<br />
If the correct voltage is not measured, the receptacle’s circuit<br />
breaker is not receiving voltage. Check the condition of the wiring<br />
between the receptacle’s circuit breaker and the terminal strip.<br />
<strong>Repair</strong>/replace the wiring as needed.<br />
If the correct voltage is measured, continue.<br />
6.29.2 Make sure the receptacle’s circuit breaker is in the ON position.<br />
6.29.3 Using the AC voltage setting on the multimeter, measure the outgoing<br />
voltage from the receptacle’s circuit breaker by measuring between the<br />
outgoing wire (c) and the wires (b) of the terminal strip. There should<br />
be 115V or 230V±10% depending on model.<br />
If the correct voltage is not measured, the receptacle’s circuit<br />
breaker is not functioning. Confirm that receptacle’s circuit<br />
breaker is malfunctioning by checking its continuity. Replace the<br />
circuit breaker if needed.<br />
If the correct voltage is measured, continue troubleshooting by<br />
checking the earth-leakage circuit breaker.<br />
b<br />
1000<br />
F 200 V<br />
20<br />
2<br />
200m<br />
V- COM<br />
A<br />
1000<br />
F 200 V<br />
20<br />
2<br />
200m<br />
V- COM<br />
118<br />
A<br />
a<br />
c<br />
wc_gr003081