Electrical <strong>Troubleshooting</strong> Procedures <strong>LTC</strong> <strong>Repair</strong><br />

6.28 Checking Voltage at the Receptacle<br />

See Graphic: wc_gr003791<br />

WARNING<br />

Electric shock hazard. Only qualified personnel should conduct this<br />

test.<br />

Complete this test with the machine running and both the main circuit<br />

breaker and the receptacle circuit breaker in the ON position.<br />

6.28.1 Using the AC voltage setting on the multimeter, test the receptacle for<br />

115V±10% on 0009379 machines; 230V±10% on 0009377 and<br />

0009485 machines.<br />

6.28.2 If the correct voltage is not measured at the front of the receptacle, test<br />

for voltage at the back of the receptacle. If the correct voltage is<br />

measured at the back of the receptacle but not at the front, the<br />

receptacle has failed; replace it.<br />

116