Maintenance 5.3 Batterry 5.3.1 Check acid level: 1. Remove battery cover. 2. Check acid level, if necessary top up with distilled water. 3. Secure battery cover. Do not close venting opening! Note: Only replace defective batteries with original Wacker batteries. Standard batteries are not suitable for the high vibration loads. 4. When changing the battery: T00997GB.fm 38 Removal: First disconnect negativ, then positive terminal of battery. Assembly. First connect positive, then negative terminal of battery. When using starting sprays etc., see chapter operation.
5.4 Hydraulic control 5.4.1 Check oil level: 1. Move centre pole into vertical position. 2. Open filler bore (26). T00997GB.fm 39 Maintenance 3. Oil level must be at mark, if necesary top up with hydraulic oil Fuchs Renolin MR 520. 4. Close filler bore (26). 5.4.2 Venting hydraulic control: 1. Remove apron (28) by undoing the screws (29). 2. Move centre pole into vertical position, move shift lever (6) right into the reverse position, open filler bore (26). 3. Loosen connecting screw (27). 4. Slowly push the shift lever (6) into forward motion direction until hydraulic oil emerges bubblefree at the connection screw. 5. Tighten connecting screw (27), mount apron (28). 6. If necessary, top up with Fuchs Renolin MR 520, seal filler bore (26).
- Page 1 and 2: Operator´s Manual 0226267en 002 03
- Page 3 and 4: 1 Foreword 1 Foreword This operator
- Page 5 and 6: 5 Table Of Contents 6.1 Forward spe
- Page 7 and 8: DPU 2 Safety 2 Safety 2.1 Principle
- Page 9 and 10: DPU 2 Safety Exclusion of liability
- Page 11 and 12: DPU 2 Safety 2.3 Protective gear Wo
- Page 13 and 14: DPU 2 Safety Work environment Famil
- Page 15 and 16: DPU 2 Safety Avoiding crushing When
- Page 17 and 18: DPU 2 Safety Safety precautions whe
- Page 19 and 20: DPU 2 Safety Working on the battery
- Page 21 and 22: DPU 2 Safety Pos. Label Description
- Page 23 and 24: TD00692GB.fm 23 Technical Data Batt
- Page 25 and 26: 2.3 Description of function T00994G
- Page 27 and 28: Transport to work site /Recommendat
- Page 29 and 30: 4. Operation 4.1 Starting 4.1.1 Con
- Page 31 and 32: 4.3 Switching off T00996GB.fm 31 Op
- Page 33 and 34: 4.6 Mechanical oil pressure control
- Page 35 and 36: 4.8 Additional notes on starting at
- Page 37: 5.2 Engine oil 5.2.1 Check oil leve
- Page 41 and 42: 5.6 Exciter V-belt T00997GB.fm 41 M
- Page 43 and 44: 6.5 The charge control lamp will no
- Page 45 and 46: 3 Disposal 3.1 Disposal of batterie
- Page 47: Manufacturer Wacker Neuson SE Preu
Maintenance<br />
5.3 Batterry<br />
5.3.1 Check acid level:<br />
1. Remove battery cover.<br />
2. Check acid level, if necessary top up with distilled water.<br />
3. Secure battery cover.<br />
Do not close venting opening!<br />
Note: Only replace defective batteries with original <strong>Wacker</strong> batteries.<br />
Standard batteries are not suitable for the high vibration loads.<br />
4. When changing the battery:<br />
T00997GB.fm 38<br />
Removal: First disconnect negativ, then positive terminal of battery.<br />
Assembly. First connect positive, then negative terminal of battery.<br />
When using starting sprays etc., see chapter operation.