21.08.2013 Views

SILAC® Siemens Industrial Linear Accelerator

SILAC® Siemens Industrial Linear Accelerator

SILAC® Siemens Industrial Linear Accelerator

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Main Customer Benefits<br />

◾ Dual energy for enhanced material detection<br />

◾ Advanced energy selection for wide range of<br />

applications and samples<br />

◾ Adjustable operation scheme<br />

Pulse length<br />

Pulse repetition rate<br />

Dose rate<br />

Energy<br />

Configuration –<br />

Customizing<br />

Size H [cm]<br />

W [cm]<br />

D [cm]<br />

Leakage radiation weight Ratio 90° to central beam in<br />

1 m distance p weight [kg]<br />

Max. dose rate<br />

(measured in water,<br />

1 m distance)<br />

1 MeV [Gy/min]<br />

2 MeV [Gy/min]<br />

3 MeV [Gy/min]<br />

4 MeV [Gy/min]<br />

6 MeV [Gy/min]<br />

9 MeV [Gy/min]<br />

◾ Flexible customer design<br />

Separate accelerator section available<br />

“All in one box“ for easy installation<br />

◾ Compact size and optimized weight<br />

◾ Fully digital control with solid state power section<br />

◾ Variable shielding options<br />

◾ Different primary collimation options possible<br />

Stationary Compact<br />

6 MeV 9 MeV 6 MeV 9 MeV<br />

196<br />

101<br />

193<br />

10 -6 p On request<br />

10 -3 p 2600<br />

0.2<br />

0.5<br />

1.8<br />

3<br />

9<br />

–<br />

196<br />

101<br />

193<br />

10 -6 p On request<br />

2 x 10 -3 p 2200<br />

–<br />

–<br />

–<br />

3<br />

9<br />

16<br />

On request On request<br />

10 -6 p On request 10 -6 p On request<br />

Focal spot size [mm] < 2 < 2 < 2 < 2<br />

Variable pulse adjustment Repetition rate [Hz]<br />

Pulse length [µs]<br />

Environment for usage Temperature [°C]<br />

(other temperatures on request)<br />

Rel. humidity [%]<br />

Protection class [IP rating]<br />

Impact resistance<br />

Vibrations<br />

Interfaces to customer:<br />

• Electrical power<br />

TN-S supply with CEE plug<br />

stucked IP66<br />

• Communications<br />

for interlock-system<br />

status indication, 24 V<br />

TTL activation and<br />

triggering ethernet<br />

ext. control and<br />

trigger under reserve<br />

• Cooling system<br />

plugs<br />

(for customer equipment)<br />

Voltage [VAC]<br />

Current [A]<br />

1 x 15-pin SUB-D stucked IP66<br />

1 x 25-pin SUB-D stucked IP66<br />

1 x RJ45 Cat6 stucked IP66<br />

4 x 5V TNC stucked IP66<br />

1 x 9-pin SUB-D stucked IP66<br />

Pressure [bar]<br />

Temperature [°C]<br />

Water flow [l/min]<br />

Image quality DIN EN 462-5<br />

ASTM 1742-00<br />

20-300<br />

1-4 µs<br />

10-30<br />

10-85<br />

66<br />

20 g<br />

2 g<br />

400<br />

32<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

5-6<br />

16-30<br />

30-40<br />

See above<br />

See above<br />

20-300<br />

1-4 µs<br />

10-30<br />

10-85<br />

66<br />

20 g<br />

2 g<br />

400<br />

32<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

5-6<br />

16-30<br />

30-40<br />

See above<br />

See above<br />

0.2<br />

0.5<br />

1.8<br />

3<br />

9<br />

–<br />

20-300<br />

1-4 µs<br />

10-30<br />

10-85<br />

66<br />

20 g<br />

2 g<br />

400<br />

32<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

5-6<br />

On request<br />

On request<br />

See above<br />

See above<br />

Power consumption Power [kW] 15 15 15 15<br />

<strong>SILAC®</strong> <strong>SILAC®</strong> control and power unit<br />

<strong>SILAC®</strong> RF-unit<br />

<strong>SILAC®</strong> accelerator unit<br />

Mechanical components Collimator internal<br />

Adjusted aperture<br />

Controls and operation Dual energy switch – interlaced<br />

User interface and control software<br />

Others Installation and system integration<br />

R&D package<br />

Standards and Laws<br />

All <strong>SILAC®</strong> models are designed and manufactured<br />

in accordance with:<br />

All in One All in One<br />

On request<br />

On request<br />

On request<br />

Yes<br />

Yes<br />

On request<br />

On request<br />

On request<br />

On request<br />

Yes<br />

Yes<br />

On request<br />

Compact unit<br />

Separate<br />

radiation head<br />

On request<br />

On request<br />

Yes<br />

Yes<br />

Yes<br />

On request<br />

–<br />

–<br />

–<br />

3<br />

9<br />

16<br />

20-300<br />

1-4 µs<br />

10-30<br />

10-85<br />

66<br />

20 g<br />

2 g<br />

400<br />

32<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

5-6<br />

On request<br />

On request<br />

See above<br />

See above<br />

Compact unit<br />

Separate<br />

radiation head<br />

On request<br />

On request<br />

Yes<br />

Yes<br />

Yes<br />

On request<br />

Low Voltage Directive 2006/95/EC and EMC<br />

Directive 2004/108/EC (EC Declaration of Conformity),<br />

other regulations on request<br />