INSTALLATION/SETUP FABRICATOR <strong>211i</strong><br />
3.01 Environment<br />
This unit is designed for use in environments with<br />
increased hazard of electric shock as outlined in EN<br />
60974.1. Additional safety precautions may be required<br />
when using unit in an environment with increased<br />
hazard of electric shock. Please refer to relevant local<br />
standards for further information prior to using in such<br />
areas.<br />
A. Examples of environments with increased hazard of<br />
electric shock are:<br />
1. In locations in which freedom of movement<br />
is restricted, so that the operator is forced to<br />
perform the work in a cramped (kneeling, sitting<br />
or lying) position with physical contact with<br />
conductive parts.<br />
2. In locations which are fully or partially limited<br />
by conductive elements, and in which there is<br />
a high risk of unavoidable or accidental contact<br />
by the operator.<br />
3. In wet or damp hot locations where humidity<br />
or perspiration considerably reduces the skin<br />
resistance of the human body and the insulation<br />
properties of accessories.<br />
B. Environments with increased hazard of electric<br />
shock do not include places where electrically conductive<br />
parts in the near vicinity of the operator, which can<br />
cause increased hazard, have been insulated.<br />
3.02 Location<br />
SECTION 3: INSTALLATION OPERATION AND SETUP<br />
Be sure to locate the welder according to the following<br />
guidelines:<br />
A. In areas, free from moisture and dust.<br />
B. Ambient temperature between 0°C (32°F) to 40°C<br />
(104°F).<br />
C. In areas, free from oil, steam and corrosive gases.<br />
D. In areas, not subjected to abnormal vibration or<br />
shock.<br />
E. In areas, not exposed to direct sunlight or rain.<br />
F. Place at a distance of 1 foot or more from walls or<br />
similar that could restrict natural air flow for cooling.<br />
G. The enclosure design of this power source meets<br />
the requirements of IP23S as outlined in EN 60529.<br />
H. Precautions must be taken against the power source<br />
toppling over. The power source must be located on<br />
a suitable horizontal surface in the upright position<br />
when in use.<br />
WARNING<br />
This equipment should be electrically connected<br />
by a qualified electrician.<br />
3.03 Ventilation<br />
<strong>Manual</strong> 0-5225 3-1 INSTALLATION/SETUP<br />
!<br />
WARNING<br />
Since the inhalation of welding fumes can<br />
be harmful, ensure that the welding area is<br />
effectively ventilated.<br />
3.04 Mains Supply Voltage<br />
Requirements<br />
The Mains supply voltage<br />
should be within ± 15% of the rated Mains supply voltage.<br />
Too low of a supply voltage may cause poor welding<br />
performance or wirefeeder malfunction. Too high of a<br />
supply voltage will cause components to overheat and<br />
possibly fail.<br />
WARNING<br />
The Fabricator <strong>211i</strong> must be electrically<br />
connected by a qualified electrical tradesperson.<br />
Damage to the PCA (Power Control<br />
Assembly) could occur if 276 VAC or higher<br />
is applied to the Primary Power Cable