20.08.2013 Views

DocLib_42_0-4905 ArcMaster 400MST CE.pdf - Victor Technologies ...

DocLib_42_0-4905 ArcMaster 400MST CE.pdf - Victor Technologies ...

DocLib_42_0-4905 ArcMaster 400MST CE.pdf - Victor Technologies ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SECTION 12: POWER SOUR<strong>CE</strong> ERROR CODES<br />

Description Possible Cause Remedy Remarks<br />

1 E01 error code displayed A The Welding Power A Let Power Source Weld current ceases.<br />

Temperature sensor TH1 Source’s duty cycle cool down then keep Buzzer sounds<br />

(protects IGBTs) is greater has been exceeded. within its duty cycle. constantly.<br />

than 80ºC for about 1 B Fan ceases to B Have an accredited Fan operates at max<br />

second.<br />

operate.<br />

Thermal Arc Service speed.<br />

C<br />

C Agent investigate. E01 resets when TH1<br />

Air flow is restricted Unblock vents then decreases<br />

by vents being let Power Source to 70ºC for about 30<br />

blocked.<br />

cool down. seconds.<br />

2 E02 error code displayed A The Welding Power A Let Power Source Weld current ceases.<br />

Temperature sensor TH2 Source’s duty cycle cool down then keep Buzzer sounds<br />

(protects secondary has been exceeded. within its duty cycle. constantly.<br />

diodes) is greater than B Fan ceases to B Have an accredited Fan operates at max<br />

80ºC for about 1 second. operate.<br />

Thermal Arc Service speed.<br />

C<br />

Agent investigate. E02 resets when TH1<br />

Air flow is restricted C Unblock vents then decreases to 70ºC for<br />

by vents being let Power Source about 30 seconds.<br />

blocked.<br />

cool down.<br />

3 E03 error code displayed A Primary current is A Reduce length of Weld current ceases.<br />

Primary (input) current too high because welding arc. Buzzer sounds<br />

too high.<br />

welding arc is too<br />

constantly.<br />

B long.<br />

B Have an accredited Switch machine OFF<br />

Mains supply Thermal Arc Service then ON to reset E03<br />

voltage is<br />

Agent or a qualified error.<br />

more than 10% electrician check for<br />

below<br />

low<br />

nominal voltage. Mains voltage.<br />

4 E04 error code displayed TIG torch cable Reduce the length of Weld current ceases.<br />

Output voltage exceeds and/or work lead are the TIG torch cable Buzzer sounds<br />

the secondary voltage too long or leads are and/or work lead or constantly.<br />

specification.<br />

coiled.<br />

un-coiled leads. Switch machine off<br />

then on to reset E04<br />

error.<br />

5 E11 error code displayed Primary supply Have an accredited Weld current ceases.<br />

Over Primary supply voltage is greater Thermal Arc Service Buzzer sounds<br />

(input) voltage at primary than the nominal Agent or a qualified constantly.<br />

capacitors is exceeded for voltage plus 10%. electrician check the Error code E11<br />

one second.<br />

Primary voltage. automatically will reset<br />

when the voltage<br />

reduces.<br />

52

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!